11

NI PCIe-8255R User Manual

references for the parameters you can set for the NI-IMAQ I/O device
in the Read/Write control. To locate the information, search for

"NI-IMAQ I/O"

in LabVIEW Help.

Specifications

These specifications are typical at 25 °C, unless otherwise stated.

Power Requirements

IEEE 1394 bus power

1

........................... 18 W, maximum

(shared by both ports)

Isolated supply

2

...................................... 5 VDC to 30 VDC

Camera interface

3

................................... IEEE 1394b, compatible with

IEEE 1394a cameras

TTL Inputs and Outputs

Digital logic levels

TTL Inputs

Number of channels ............................... 2

Maximum pulse rate............................... 2 MHz

Minimum pulse detected ........................ 500 ns

Power-on state........................................ Input (high-impedance)

61.9 k

Ω pull-up to 5V

1

The bus power specification assumes that power is provided to the NI 8255R device from the host computer power supply via

the ATX power connector. If power is not supplied through the ATX power connector, camera power is supplied by the PCIe
bus and should be limited to 3 W, shared by both ports.

2

Do not draw more than 100 mA from 30 V isolated outputs. Do not draw more than 50 mA from 5 V isolated outputs.

3

To connect an IEEE 1394a camera to the NI 8255R, you will need a 6-pin to 9-pin cable or a 6-pin to 9-pin adapter.

Level

Minimum

Maximum

Input low voltage (V

IL

)

0 V

0.5 V

Input high voltage (V

IH

)

2.2 V

5 V

Output low voltage (V

OL

), at 5 mA

0.4 V

Output high voltage (V

OH

), at 5 mA

2.4 V

Advertising