Draining the Water Heater

Freeze Protection

Where the water heater may be exposed to
freezing conditions, even for a short
period of time, be sure to drain all water
from the unit as instructed above.

Exposure to freezing conditions can occur
from down draft of venting system or
from installation in areas exposed to cold
air.
The water heater is equipped with a Freeze

Protection Electric Heater. As long as the

electricity is supplied to the water heater, it

prevents freezing inside the water heater up

to an ambient temperature of approximately

minus 30°F (without wind-chill factor)
This device only protects the internal

components of the water heater. It does

NOT protect piping and valves. Therefore,

piping and valves should be wrapped with

insulation material as instructed on page 17.

Another method of freeze prevention is by

running a small volume of water. Running

water will protect the water heater, piping

and valves.
Follow the steps below to ensure proper

water flow through the water heater and

piping:

Turn off the switch on the remote

control.

Close the gas shut-off valve.

Open the hot water faucet slightly until

a stream of approximately 1/8” is
flowing. Be sure to check the flow
periodically.

WARNING: Failure

to drain the water

heater can cause serious

damage to the water

heater as well as

personal injury.

Below are instructions for draining water
out of the water heater.

Turn off the switch on the remote

control.

Close the gas shut-off valve(s).

Turn the on/off switch to the OFF

position and disconnect breaker at least
10 seconds after step #1.

Open all hot water faucets. Before

proceeding to the next step, make sure
that COLD water is coming out of all
hot water faucets.

Close the water shut-off valve.

Using a suitable container to catch

water, remove the water filter from
heater. Attach a garden hose to the
drain valve installed in the hot water
outlet line and direct the stream of
water to a suitable drain where it will
cause no damage. Approximately 21oz
of water will be drained. Leave water
heater as is until next use.

To put the water heater back into
operation after draining, follow the steps
below.

Reinstall the water filter. Close the hot

water outlet drain valve.

Open the water shut-off valve and close

again after making sure that water
comes out from hot water faucets.
(This step is to remove air from the
water lines.)

Reconnect the breaker and turn the

on/off switch to the ON position, fully
open the gas shut-off valve and the
water shut-off valve.

NOTICE: The water heater may not
operate unless the above procedure is
followed correctly.

To Hot Water

Faucet(s)

°F

PRIORITY

POWER

ON/OFF

Draining the water heater

WARNING: Failure

to follow these

instructions while

draining the water

heater can cause serious

damage to the water

heater as well as

personal injury

including scalding.

NOTICE

: DO NOT

unplug the electric

power supply cord for

freeze protection.

Care and cleaning of the water heater.