The vdsl performance screen appears (see, Figure 5-3, Table 5-2 – RAD Data comm 4-Wire Symmetrical VDSL Modem ASM-60 User Manual

Page 44: List

Advertising
background image

Chapter 5 Diagnostics

ASM-60 Installation and Operation Manual

5-4

Displaying the VDSL Performance Diagnostics

VDSL Performance

Line A Lock Status: SYNC

Line A Avg. Snr.: 34

Line A BER pre FEC: 0.000E+00

Line A BER after FEC: 0.000E+00

Line B Lock Status: SYNC

Line B Avg. Snr.: 34

Line B BER pre FEC: 0.000E+00

Line B BER after FEC: 0.000E+00

>

ESC - previous menu ; ! - main menu ; & - exit terminal

-------------------------------------------------------

Figure 5-3. VDSL Performance Screen

Figure 5-3

shows VDSL Performance Monitoring screen, as it appears 15 seconds

after the ASM-60 power-up.

Table 5-2. ASM-60 Performance Monitoring Parameters

Display Description

Line A/B Lock Status

This parameter provides the information on the status of the
connection between the ASM-60 units (synchronized or not

synchronized). This value is updated every second.

Line A/B Avg. Snr.

This parameter provides the avarage signal-to-noise ratio in the line.

Line A/B BER pre FEC

This parameter provides the bit error rate before the Forward Error

Correction is performed.

Line A/B BER after FEC

This parameter provides the bit error rate after the Forward Error

Correction is performed.

Note

Advertising