Ockford, Osgate, Ccessories – Rockford Fosgate PSD-1 User Manual

Page 18: Symptom diagnosis remedy, Psd c, Cc-1188)

Advertising
background image

– 14 –

T

R O U B L E S H O O T I N G

Symptom

Diagnosis

Remedy

PSD does not
turn on
(Remote
Disabled)

TROUBLE- S

H
O
O

T

I

N
G

Remote Turn-On wire
must be used with a
250m

2

, 500m or 250m

Data Interface Cable
between amplifier and
PSD is damaged

Amplifier is not work-
ing properly

Voltage applied to the
PSD Remote Turn-On
wire is not between 8
and 15.5 or there is no
voltage present

Optional switch (if used)
is damaged or in the
“OFF” position

Data Interface Cable
between amplifier and
PSD is damaged

Amplifier is not work-
ing properly

R

OCKFORD

F

OSGATE

A

CCESSORIES

PSD C

ABLES

(CC-1188)

20 foot 8-conductor cables are available separately for the connection
of an additional mono amplifier to Punch Status Display. This will allow
the PSD to accommodate a pair of Mono amplifiers operating individu-
ally or a pair of Mono amplifiers bridged.

Enable Remote jumper and
connect Remote Turn-On
(blue wire) to a source of
switched +12V

Check connections, substitute
with known working cable
and repair or replace as nec-
essary

Check connections, substitute
with known working ampli-
fier and repair or replace as
necessary

Check wiring and repair if
necessary. If voltage is above
15.5 volts, have the electrical
system inspected by an au-
thorized car service center

Bypass switch – if PSD turns
on, check connections and
switch position and repair or
replace as necessary

Check connections, substitute
with known working cable and
repair or replace as necessary

Check connections, substitute
with known working ampli-
fier and repair or replace as
necessary

PSD does not
turn on
(Remote
Enabled)

Advertising