WATER-TUBE POOL HEATERS

PART 1 - GENERAL

1.1 SUMMARY

A. Section includes condensing, gas-fired copper finned-tube, gas domestic pool heaters

Specifier Note: Use as needed

B. Related

Sections

1. Building Services Piping – Division 22 10 00
2. Breeching, Chimneys, and Stacks (Venting) – Division 23 51 00
3. Electrical – Division 23 09 33

1.2 REFERENCES

A. ANSI Z21.10.3/CSA 4.3
B. ASME, Sections IV and VIII
C. 2006 UMC, Section 1107.6
D. ANSI/ASHRAE 15-1994, Section 8.13.6
E. National Fuel Gas Code, ANSI Z223.1/NFPA 54
F. National Electrical Code, ANSI/NFPA 70
G. ASME CSD-1, 2009 (when required)

1.3 SUBMITTALS

A. Product data sheet (including dimensions, rated capacities, shipping weights, accessories)
B. Wiring

diagram

C. Warranty information
D. Installation and operating instructions

1.4 QUALITY

ASSURANCE

A. Regulatory

Requirements

1. ANSI Z21.10.3/CSA 4.3
2. Local and national air quality regulations for low NOx (0-20 PPM NOx emissions) pool heaters

B. Certifications

1. CSA
2. ASME HLW Stamp and National Board Listed – Primary
3. ASME U Stamp and National Board Listed – Secondary
4. ISO

9001

1.5 WARRANTY

A. Limited one-year warranty from date of installation
B. Limited twenty-five-year thermal shock warranty
C. Limited five-year primary heat exchanger warranty
D. Limited ten-year secondary heat exchanger warranty

PART 2 - PRODUCTS

2.1 MANUFACTURER

A. Raypak,

Inc.

1. Contact: 2151 Eastman Ave., Oxnard, CA 93030; Telephone: (805) 278-5300;

Fax: (800) 872-9725; Web site: www.raypak.com

2. Product: XTherm™ condensing copper finned-tube pool heater(s)

Catalog No.: 6000.63A
Effective: 9-01-09
Replaces: 9-15-08

XTHERM™, TYPE WHP - MODELS 1005-2005

SUGGESTED SPECIFICATIONS