66 tankless series, Specifications – Rheem 11 User Manual

Page 2

Advertising
background image

66 TANKLESS SERIES

RTG-66DVN

11,000-

Indoor

85° to

4.0

6.6

8.4

3/4

3/4

25-5/8

13-7/8

9-7/8

3 by 5

54

.82

$223/$374

180,000

Direct Vent

140° F

CONCENTRIC

RHEEM TANKLESS WATER HEATERS FOR 2-3 BATHROOM HOMES

All models are available in Natural Gas and Propane (LP).
For Propane replace the N with P when ordering.

• Factory set maximum temperature is 120° F. See Use and Care Manual for setting.
• Consult factory for information on sizing the application.
Vent Termination Kits are required for Direct Vent models. Contact your distributor for details.

Temperature Rise (°F)

Model Number

35°

45°

50°

60°

70°

77°

80°

90° 100°

RTG-66 Water Flow (GPM)

8.4

6.6

5.9

4.9

4.2

4.0

3.6

3.3

2.9

Above estimates are for sizing purposes only.

Proper gas pressure must be ensured to supply tankless gas water heaters – up to 180,000 BTU
for RTG-66 models. (Consult your gas supplier)

Rheem Heating, Cooling & Water Heating
101 Bell Road • Montgomery, AL 36117-4305
1-866-720-2076 • www.rheemtankless.com

Rheem Canada Ltd./Ltée • Water Heater Division
128 Barton Street West, Hamilton, Ontario L8N 3P3

Rheem manufactures residential & commercial heating,
cooling & water heating products.

Printed in U.S.A.

07/08 WP

Form No. 101-50-66

These units are designed to meet or exceed ANSI (American National Standards Institute)
requirements and have been tested according to D.O.E. test procedures and meet or
exceed the energy efficiency requirements of NAECA, ASHRAE standard 90, ICC Code and
all state energy efficiency performance criteria for energy consuming appliances.

Before purchasing this appliance, read important energy cost and efficiency information
available from your supplier.

In keeping with its policy of continuous progress and product improvement,
Rheem reserves the right to make changes without notice.

Water Heater Flow Rate Curves

0

1

2

3

4

5

6

7

8

9

10

15

20

25

30

35

40

45

50

55

60

70

80

90

100

120

140

Delta-T

G

PM

Max Flow

Specifications

DESCRIPTION

FEATURES

ROUGHING IN DIMENSIONS (SHOWN IN INCHES)

ENERGY INFO.

GAS

WATER FLOW RATE

VENT

SHIP.

D.O.E. ANN.

MODEL

INPUT

TEMP.

GPM @ 77° GPM @ 45° GPM @ 35°

CONNECTION

DIAMETER

WEIGHT

ENERGY

OP. COST

NUMBER

BTU/HR.

TYPE

RANGE

RISE MAX. RISE MAX. RISE MAX.

WATER

GAS

HEIGHT

WIDTH

DEPTH

(INCHES)

(LBS.)

FACTOR

NAT/LP

Energy Factor and Average Annual Operating Costs based on D.O.E.
(Department of Energy) test procedures. D.O.E. national average fuel rate
natural gas $1.218/therm; LP $1.87/gallon

.

®

Advertising
This manual is related to the following products: