7.3. Starting up

Turn on the water supply tap 2 Fig.5.

Turn the main switch 1; the pump is activated, filling

the boiler.

When the water reaches the correct level, the

pump stops.

Turn the main switch 2 to begin heating the water

in the boiler then turn each one until water begins
to flow from them.

Wait for the machine to reach its working pressure

and to reach the correct thermal balance.

7. OPERATION

7.1. Controls (Fig.8)

1 Main switch

Two-position switch with led.
Turn on the switch (led on) the machine is turned
(apart from the boiler) and the pump is turned on
to fill the boiler;

2 Boiler resistance switch

Two-position switch with led.
On activating the switch (the led comes on) and
power is supplied to the resistance for the boiler
water.

3 Cup heating resistance switch
Two-position switch with led.
By turning on the switch (led on), the cup heating

resistance is power supplied.

4A Coffee dispensing switch (mod.S)

Two-position switch:

With switch ON, coffee is dispensed;

With switch OFF, dispensing of coffee is interrup-

ted.

4B Coffee Dispensing Electronic Panel (mod. E)
This panel features 5 buttons for each dispenser

(max 4) and 5 LEDs consisting of the following:

4 (A-B-C-D) buttons for start/stop dispensing the

programmed coffee dose

1 (E) button for:
- Stop dispensing any dose
- Start in continuous mode
- Initialize dose programming for self-learning if

pressed for about 8 sec.(If the function is ena-
bled)

Each time a coffee is dispensed, the LED of the

relative button lights up.

During dose programming, the LED of the 5

th

button flashes rapidly.

If the dose is supplied irregularly or the volumetric

counter is malfunctioning, the LED of the pressed
button flashes dispensing the dose on a time ba-
sis.

4C Coffee dispensing control lever (mod.L)
The lever is usually placed in high position.
Activate hte lever by pushing it down to obtain

coffee dispensing.

5A Hot woter button (mod.S)
Hot water switch (picking up directly from the boi-

ler) with two positions:

With switch ON, the LED flashes and hot water is

dispensed directly from the boiler.

With switch OFF, the LED switches off and dispen-

sing stops.


5B Hot water button (mod.E)
When the button is pressed, hot water is dispensed

directly from the boiler for the set time or until the
button is pressed again.

If you press the button for 2 seconds, dispensing

is continuous and only stops when the button is
pressed again.

Dispensing is discontinued automatically after 30

and 60 seconds, respectively.

5C Hot water supply tap (mod.L)
Tap: turn a antclockwise to open and clockwise to

close.

Safety Devices
Dispensing cannot be carried out if the machine

has not reached the operating pressure or tempe-
rature at least once, and each time that the boiler
pressure drops too much.

6 Steam supply handwheel.
Tap: turn in an anticlockwise direction to open and

clockwise to close.

7 Supplementary manual water filling button

positioned under the discharge basin.
Press down to fill the boiler.

8 Valved gas power tap (models with gas hea-

ting).
Open: vertical position;
Closed: turn 90° in clockwise direction.

9 Piezoelectric button (models with gas hea-

ting).
Firing button: press down firmly to give off the
spark to light the gas for the burner.

7.2. Control instruments (Fig.8)

10 Gauge with mobile needle on a fixed dial with a

double scale.
Visual control of the pump (lower manometer ) and
of the boiler pressure (upper manometer) (mod.
E-S).

11 Minimum and maximum water level indicator .

Visual control of water level in boiler.

12 Control window (models with gas heating).

Visual control of lighting and functioning of the
flame of the gas burner.

Advertising