Rinnai R98LSI-ASME User Manual

Rinnai Water boiler

Advertising
background image

R98LSiASME (VA3237FFU-ASME)

Type of Appliance

Rinnai model number

Operation / Installation

Exhaust system

Minimum/Maximum Gas Rate (Input)

Electrical


Electrical Consumption



Ignition System

Hot Water Capacity

Temperature


Temperature (without remote)

Approved Gas Types

Thermal Efficiency

Service Connections



Water Flow Control

Minimum/Maximum Water Supply Pressure

Temperature controlled, continuous flow, gas hot water system

REU-VA3237FFU-ASME

Forced combustion / Indoor only

Direct vent

19,000 - 237,000 BTU/h (Natural Gas or Propane)

Appliance:

AC 120 Volts - 60 Hz

Remote Control:

DC 12 Volts

Normal

99

watts

Standby 2

watts

Anti-frost protection

116 watts

Direct electronic ignition

0.6 to 7.9 GPM (50° F rise)

0.9 to 9.8 GPM (35° F rise)

98° - 140° F (98° - 185° F available with the MCC-91 controller for
commercial and hydronic applications)

120° F (factory default)

Natural or Propane (ensure unit matches gas type)

Natural Gas: 84%

Propane: 84%

Gas supply: 3/4 inch MNPT
Cold water inlet: 3/4 inch MNPT
Hot water outlet: 3/4 inch MNPT

Water flow sensor, electronic water control and by-pass control

15 - 150 PSI (50 PSI or above is recommended for maximum flow)

© 2010 Rinnai Corporation

R98LSiASME SP 4/2010

FLOW TABLE

Water Flow
Capacity Curve

R

This model has been built in accordance with the requirements of
the ASME Boiler and Pressure Vessel Code and has received the
Certificate of Authorization from the National Board. The heat
exchanger has the NB and the HLW stamps.

0

1

2

3

4

5

6

7

8

9

10

0

25

50

75

100

125

150

delta T-Temperature Rise(F)

W

a

te

r F

lo

w

R

a

te

(

G

PM

Water Flow (gpm)

delta T - Temperature Rise (ºF)

Advertising