Electric chain saw, Cleaning and maintenance – Remington LNT-2: 076728K User Manual

Page 12

Advertising
background image

12

107990

ELECTRIC CHAIN SAW

®

For more information, visit www.desatech.com

CLEANING SAW BODY

CLEANING AND
MAINTENANCE

Guide Bar

With Uneven

Wear

Figure 17 - Guide Bar Cross Section Show-
ing Uneven Bar Wear

Guide Bar
Groove

Guide Bar

NOTICE: Below are instructions
for servicing your chain saw. Any
servicing not mentioned below
should be done by an authorized
service center.

WARNING: Unplug chain saw

from power source before servic-
ing. Severe injury or death could
occur from electrical shock or
body contact with moving chain.

WARNING: Cutting edges on

chain are sharp. Use protective
gloves when handling chain.

WARNING: When cleaning

saw body,
• do not submerge saw in any

liquids

• do not use products that con-

tain ammonia, chlorine, or
abrasives

• do not use chlorinated clean-

ing solvents, carbon tetrachlo-
ride, kerosene, or gasoline

CARE OF GUIDE BAR

Uneven bar wear causes most guide bar
problems. Incorrect sharpening of chain
cutter and depth gauge settings often cause
this. When bar wears unevenly, it widens
guide bar groove (see Figure 17). This causes
chain clatter and rivet popping. Saw will not
cut straight. Replace guide bar if this occurs.

Inspect guide bar before sharpening chain.
A worn or damaged guide bar is unsafe. A
worn or damaged guide bar will damage
chain. It will also make cutting harder.

Keep saw body clean. Use a soft cloth damp-
ened with a mild soap and water mixture.
Wipe saw body to clean.

Normal Guide

Bar

Figure 18 - Guide Bar Maintenance

Flat File

Burr

Oil Slot

Cleaning Groove With
Putty Knife

Guide Bar

Normal Guide Bar Maintenance

1.

Remove guide bar from chain saw.

2.

Remove sawdust from guide bar
groove periodically. Use putty knife or
wire.

3.

Clean oil slots after each day of use.

4.

Remove burrs from sides of guide bar.
Use flat file to make side edges square.

Replace guide bar when

• bar is bent or cracked

• inside groove of bar is badly worn

Note:

When replacing guide bar, see Re-

placement Parts and Accessories, page 19,
for proper bar.

Advertising