6 2-wire call signal – RTS SSA-424 User Manual

Page 14

Advertising
background image

14 SSA-424 U

SER

M

ANUAL

2.6

2-W

IRE

C

ALL

S

IGNAL

2.6.1

C

ALL

S

IGNAL

C

ONNECTIONS

FOR

A

UDIOCOM

,

RTS TW

AND

C

LEAR

-C

OM

The call signals are superimposed on the audio
signal, so no separate call signal connections are
required. However, make sure that a call enable
switch or jumper is installed for Clear-Com applica-
tions as shown in Figures 5 and 6.

2.6.2

C

ALL

S

IGNAL

C

ONNECTIONS

FOR

O

THER

2-

W

IRE

C

OMMUNICATION

S

YSTEM

Any other 2-wire device must be able to generate
and receive a 20kHz signal superimposed on the
audio as follows:

Balanced Audio Configuration

Pin1:

No connection

Pin 2:

Balanced 20 kHz + Input/Output

Pin 3:

Balanced 20 kHz - Input/Output

SSA-424 Signal Specifications for balanced configu-
ration:

SSA-424 Receive: 20kHz ±100 Hz, 100mV p-p
SSA-424 Send: 20 kHz ±800 Hz, 1V p-p

Unbalanced Configuration 1

Pin 1:

20 kHz Common

Pin 2:

20 kHz Input/Output

Pin 3:

No connection

Unbalanced Configuration 2

Pin 1:

20 kHz Common

Pin 2:

No connection

Pin 3:

20 kHz Input/Output

SSA-424 Signal Specifications for unbalanced
configurations:

SSA-424 Receive: 20 kHz ±100 Hz, 0.3Vrms
SSA-424 Send: 20 kHz ±200 Hz, 100m Vrms

Advertising