Connecting to hmon – Renesas H8S2215R User Manual

Page 15

Advertising
background image

5.3.1. Connecting To HMon

We can now attempt to connect to the target device.

• Press the Green ‘Connect’ Icon.

HMon is able to discover the internal flash configuration of the device from the FDT kernel we configured earlier. HMon also needs

information on the location of the IO registers and internal / external RAM. This information is stored in a ‘.TCF’ file. The TCF file is supplied

and registered with HEW. As it is possible to have TCF files with slightly different configurations the following dialog is displayed to allow

selection.

• Select the TCF file that applies to your RSK.

• Press <OK>.

A further dialog will be displayed to confirm if it acceptable to assume only one E8 device will be connected to the host computer while

using this project. This is the preferred operating mode. While it is possible to use more than one E8 device this is not recommended.

• Press ‘Yes’ to assume only one E8 device

is connected while in this project.

Note: If you have not followed the Quick Start Guide, additional driver messages may be displayed here. Please refer to the Quick Start

Guide for driver installation.

The following dialog allows the selection of the baud rate and power options for connection to the target board and monitor code. The

default settings are shown below. If the target board is modified with a different crystal frequency then this setting will need to be changed.

(Note in this case the kernel will also need to be re-compiled).

13

Advertising