Regency Zero Clearance Direct Vent Gas Fireplace P121/P131-LP2 User Manual

Gas fireplaces, Hi j k

Advertising
background image

P121 - P121LC/RC - P131 Zero Clearance Direct Vent Gas Fireplace

Model

P121/P131-NG2

P121/P131-LP2

Fuel Type

Natural Gas

Propane

Minimum Supply Pressure

5” W.C. (1.25 kPa)

12” W.C. (3.00 kPa)

Manifold Pressure - High

3.8” W.C. (0.95 kPa)

11” W.C. (2.74 kPa)

Manifold Pressure - Low

1.1” W.C. (0.27 kPa)

2.9” W.C. (0.72 kPa)

Orifi ce Size

#31 DMS

#50 DMS

Minimum Input

20,500 BTU/h (6.01 kW)

20,600 BTU/h (6.04 kW)

Maximum Input

40,000 BTU/h (11.72 kW)

39,000 BTU/h (11.43 kW)

Vent Sizing

4” Inner / 6-5/8” Outer

4” Inner / 6-5/8” Outer

P

Gas Line

Inlet

Electrical

Inlet

BACK

N

O

M

A

D

C

G

E

B

F

P121 See Thru

P131 Pier

P121RC Right Corner

P121LC Left Corner

Unit Dimensions

Description

P121

P121LC/RC

P131

A

Front Face Width

43-1/2”

(1105mm)

41-1/2”

(1054mm)

41-1/2”

(1054mm)

B

Total Firebox Width

46-1/4”

(1175mm)

44-1/2”

(1130mm)

44-1/2”

(1130mm)

C

Front Face Height

36” (914mm)

36” (914mm)

36” (914mm)

D

Height w/ Standoff

42” (1067mm)

42” (1067mm)

42” (1067mm)

E

Unit Depth

25” (635mm)

26-13/16”

(681mm)

25” (635mm)

F

Top Offset Depth

21-1/8”

(537mm)

21-1/8”

(537mm)

21-1/8”

(537mm)

G

Inset to Standoff

4-3/4”

(121mm)

4-3/4”

(121mm)

3” (76mm)

H

I

J

K

Combustible

Material

3”

Extension

Trim

Non-Combustible

Material *

Top of

Unit

8”

Greyed out framing will not apply to all units.

Please refer to the manual.

L

Framing Dimensions Description

P121

P121LC/RC

P131

H

Framing Width

46-3/4”

(1187mm)

45”

(1143mm)

**

45”

(1143mm)

**

I

**

Framing Height

**

42-1/2”

(1080mm)

42-1/2”

(1080mm)

42-1/2”

(1080mm)

J

**

Framing Depth

**

25” (635mm)

**

26-13/16”

(681mm)

25” (635mm)

**

K

Vent Centerline Height

42-13/16” (1072mm)

L

Framed Chase Ceiling

48-1/4” (1226mm)

M

Electrical Inlet Height

2” (51mm)

2” (51mm)

2” (51mm)

N

Electrical Inlet Inset

11-3/8”

(289mm)

13-5/16”

(338mm)

11-3/8”

(289mm)

O

Gas Connection Height

1-11/16”

(43mm)

1-11/16”

(43mm)

1-5/8” (41mm)

P

Gas Connection Inset

11-1/2”

(292mm)

11-1/2”

(292mm)

11-1/2”

(292mm)

** Refer to the manual for variations effected by fi nishing material
thickness.

P121-P131 Gas Fireplace

If the provided 3” extension trim is not installed the P121(LC/RC)/
P131 must be installed with non-combustible facing up to 8” above
the fi replace. Otherwise combustible facing may be used above the
extension trim.

Approved Venting Systems

Flex Vent Systems:

FPI AstroCap™ Flex Vent

Rigid Pipe Vent Systems:

Simpson Dura-Vent® Direct Vent GS
American Metal Products Ameri Vent
Security Secure Vent®
Selkirk Direct-Temp.

Please refer to Page 11 (Exterior Vent Terminations)

for additional guidelines on vent locations.

69

June 2007 Regency Product Specifi cations Book

Gas Fireplaces

Gas Fir

eplaces

Advertising
This manual is related to the following products: