Installation, Venting arrangements - horizontal terminations – Regency P48 User Manual

Page 14

Advertising
background image

Regency P48 Zero Clearance Direct Vent Gas Fireplace

14

INSTALLATION

VENTING ARRANGEMENTS - HORIZONTAL TERMINATIONS

SIMPSON DURA-VENT DIRECT VENT GS SYSTEM and

REGENCY DIRECT VENT SYSTEM (FLEX)

(Propane & Natural Gas)

The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 45

o

and one 90

o

elbow (two 45

o

elbows equal

one 90

o

elbow).

Note: Must use optional flue adapter (Part # 370-994) when using Simpson Dura-Vent pipe. (Refer to page 13.)

Simpson Dura-Vent
5" inner diameter
8" outer diameter

Regency Flex Vent
5" inner diameter
8" outer diameter

Maintain clearances to combustibles as listed on pages 6 to 9.

Horizontal vent must be supported every 3 feet.

Firestops are required at each floor level and whenever passing through a wall.

A vent guard should be used when-
ever the termination is lower than the
specified minimum or as per local
codes.

Note: Regency Direct Vent System

(Flex) is only approved for hor-
izontal terminations.