POWER VENT ASSEMBLY

INSTALLATION, START-UP AND OPERATION

1. RECEIVING EQUIPMENT

On receipt of your equipment it is suggested that you visually check for external damage to the carton. If

the carton is damaged, it is suggested that a note be made on the Bill of Lading when signing for equipment.
Remove the complete assembly from the carton if it is damaged report the damage to the carrier immediately.
Be sure that you receive the number of packages indicated on the Bill of Lading. Claims for shortages and
damages must be filed with the carrier by consignee.

Purchased parts are subject to replacement only under the manufacturer's warranty. Debits for defective

replacement parts will not be accepted and defective parts will be replaced in kind only per our standard
warranties.

When ordering parts, you must specify Model and Serial Number of the unit. When ordering under warranty

conditions, you must also specify date of Installation.

Raypak recommends that this manual be reviewed thoroughly before installing the D-2 Power Vent. If there

are any questions which this manual does not answer, please contact your local Raypak Representative.

THIS MANUAL SHOULD BE MAINTAINED IN LEGIBLE CONDITION AND KEPT ADJACENT TO THE UNIT.

2. GENERAL SPECIFICATIONS

The D-2 Power Vent Assembly is tested and certified to the latest edition of the American National Standard

ANSI Z21.56. standard for pool heaters, Z21.10.3 for water heaters and Z21.13 for boilers.

The Power Vent Assembly is a fan assisted combustion system designed for application to Raypak Pool

Heater Models 185-405. The unit, when installed as directed, is capable of operating in applications such as
through the wall venting and reduced horizontal and vertical vent pipe sizes in new and existing installations.

The D-2 Power Vent assembly includes a blower with a 120/240 volt 60 Hz 1.0/1.95A 3200 RPM motor, a

plenum complete with a draft proving switch and a motor relay. When provided for field mounting the assembly
is equipped with a wire harness.

MODEL

MINIMUM

KIT

FACTORY

SIZE

CONNECTION

NUMBER

WIRED

DIAMETER

185

4”

008086

240V

265

4”

008086

240V

335

4”

008087

240V

405

4”

008087

240V

182/181

4”

008757

120V

260/261

4”

008757

120V

330/331

4”

008758

120V

400/401

4”

008758

120V