Recommended Specifications

Water heater(s) shall be model _____________, manufactured by RHEEM-RUUD, having electrical input of __________ kW and a recovery
rate of _____________ GPH at a 100°F temperature rise. Water heater(s) shall have a storage capacity of __________ gallons. Water
heater(s) shall have the UL seal of certification and be factory equipped with an AGA/ASME rated temperature and pressure relief valve.
Tank(s) interior shall be coated with a high temperature porcelain enamel and furnished with an R-Tech resistored magnesium anode rod
rigidly supported. Water heater(s) shall meet or exceed the energy factor requirements of ASHRAE. Tanks shall have a working pressure rating
of 150 psi, and shall be completely assembled. Water heater(s) shall be equipped with copper, resistored, “screw-in” type elements. Tank shall
be insulated with 2

1

/

2

" of rigid polyurethane foam insulation. Water heater(s) shall be equipped with surface mounted thermostats each with an

integral, manual reset, high limit control. Water heater(s) shall be covered by a three year limited warranty against tank leaks.

Limited Warranty

This product features a three year limited warranty against tank leaks. Please refer to
Commercial Warranty Information brochure for complete warranty information.

DIMENSIONAL INFORMATION

(All dimensions shown in English and Metric)

MODEL

MIN.

MAX

TANK CAPACITY

A

B

APPROX. SHIPPING WT.

NUMBER

WATTS

WATTS

GALLONS

LITERS

inches

mm

inches

mm

lbs.

kgs.

ELDS30

3,000

12,000

30

114

29-1/2

750

22-1/4

565

105

48

ELDS40

3,000

12,000

38

144

31-1/2

800

23

584

135

61

ELDS52

3,000

12,000

47

178

32-1/2

813

26-1/4

667

150

68

ELD30

3,000

9,000

30

114

45-1/2

1156

17-3/4

451

90

41

ELD40

3,000

12,000

40

151

46-1/4

1175

22-1/4

565

108

49

ELD52

3,000

12,000

50

189

57

1448

22-1/4

565

127

58

ELD66

3,000

12,000

65

246

58-3/4

1492

23

584

170

77

ELD80

3,000

12,000

80

303

59

1499

24-1/2

622

200

91

ELD120

3,000

12,000

119.9

454

62-1/2

1586

28-1/4

718

330

150

ANODE ROD

COLD

WATER

CONNECITON

WATER CONNECTIONS 3/4" NPT

3/4" T&P

HOT

WATER

CONNECTION

8"

B DIA.

A

WATER

TEMPERATURE

RATINGS

Thermostat

Type:

Surface Mounted

Minimum

Temperature:
110°F

(43.3°C)

Maximum

Temperature:
170°F

(76.7°C)

High Temperature

Limit:

190°F

(87.8°C)

PRODUCT AVAILABILITY

NON-SIMULTANEOUS WIRING

SIMULTANEOUS WIRING

ELEMENT

2 OR 3 WIRE CONFIGURATION

2 WIRE CONFIGURATION

4 WIRE CONFIGURATION

WATTAGE

SINGLE OR THREE PHASE OPERATION†

SINGLE PHASE OPERATION ONLY

SINGLE OR THREE PHASE OPERATION†

(UPPER/LOWER)

208V

240V

277V

480V

208V

240V

277V

480V

208V

240V

277V

480V

3,000/3,000

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

4,000/4,000

Y

Y

Y

Y

N/A

N/A

Y

Y

Y

Y

Y

Y

4,500/4,500

Y

Y

Y

Y

N/A

N/A

N/A

Y

Y

Y

Y

Y

5,000/5,000

Y

Y

Y

Y

N/A

N/A

N/A

Y

Y

Y

Y

Y

6,000/6,000

Y

Y

Y

Y

N/A

N/A

N/A

Y

N/A

Y

Y

Y

ELECTRICAL CHARACTERISTICS

NON-SIMULTANEOUS WIRING

SIMULTANEOUS WIRING

SINGLE/THREE PHASE OPERATION†

SINGLE PHASE OPERATION

THREE PHASE OPERATION†

ELEMENT

FULL LOAD CURRENT IN AMPERES

FULL LOAD CURRENT IN AMPERES

FULL LOAD CURRENT IN AMPERES

WATTAGE

(All Terminals)

(All Terminals)

(Terminals L3 / Terminals L1 & L2)

(Upper/Lower)

208V

240V

277V*

480V

208V

240V

277V

480V

208V

240V

277V**

480V

3,000/3,000

14.4

12.5

10.8

6.3

28.8

25.0

21.7

12.5

25.0/14.4

21.7/12.5

10.8

10.8/6.3

4,000/4,000

19.2

16.7

14.4

8.3

N/A

N/A

28.9

16.7

33.3/19.2

28.9/16.7

14.4

14.4/8.3

4,500/4,500

21.6

18.8

16.2

9.4

N/A

N/A

N/A

18.8

37.5/21.6

32.5/18.8

16.2

16.2/9.4

5,000/5,000

24.0

20.8

18.1

10.4

N/A

N/A

N/A

20.8

41.7/24.0

36.1/20.8

18.1

18.0/10.4

6,000/6,000

28.8

25.0

21.7

12.5

N/A

N/A

N/A

25.0

N/A

43.3/25.0

21.7

21.7/12.5

RECOVERY CAPACITIES

– Recovery in U.S. Gallons/Hr. (GPH) and Liters/Hr. (LPH) at various temperature rises.

NON-SIMULTANEOUS WIRING

SIMULTANEOUS WIRING

40° F

60° F

80° F

100° F

120° F

40° F

60° F

80° F

100° F

120° F

(22° C)

(33° C)

(45° C)

(56° C)

(67° C)

(22° C)

(33° C)

(45° C)

(56° C)

(67° C)

GPH

LPH

GPH

LPH

GPH

LPH

GPH

LPH

GPH

LPH

GPH

LPH

GPH

LPH

GPH

LPH

GPH

LPH

GPH

LPH

30

115

20

77

15

58

12

46

10

38

61

230

41

153

30

115

24

92

20

77

41

153

27

102

20

77

16

61

14

51

81

307

54

205

41

153

32

123

27

102

46

173

30

115

23

86

18

69

15

58

91

345

61

230

46

173

36

138

30

115

51

192

34

128

25

96

20

77

17

64

101

384

68

256

51

192

41

153

34

128

61

230

41

153

30

115

24

92

20

77

122

460

81

307

61

230

49

184

41

153

ELEMENT
WATTAGE

(Upper/Lower)

3,000/3,000
4,000/4,000
4,500/4,500
5,000/5,000
6,000/6,000

* 277 Volt units are not available for three phase operation.

** 277 Volt units can be ordered in 4 wire simultaneous for single phase operation.

† Unbalanced three phase.

3KW - 12KW Electric continued.