Recommended operating conditions, Electrical characteristics – Renesas HD74UH04 User Manual

Page 3

Advertising
background image

HD74UH04

Rev.4.00, Feb.02.2004, page 3 of 6

Recommended Operating Conditions

Item

Symbol

Ratings

Unit

Supply voltage

V

CC

2 to 6

V

Input voltage

V

IN

0 to V

CC

V

Output voltage

V

OUT

0 to V

CC

V

Operating temperature

Topr

–40 to +85

°C

0 to 1000 (V

CC

= 2.0 V)

0 to 500 (V

CC

= 4.5 V)

Input rise/fall time

t

r

, t

f

0 to 400 (V

CC

= 6.0 V)

ns

Electrical Characteristics

Ta = 25°C

Ta = –40 to 85°C

tem

Symbol

V

CC

(V)

Min

Typ

Max

Min

Max

Unit

Test Conditions

2.0

1.5

1.5

4.5

3.15

3.15

V

IH

6.0

4.2

4.2

V

2.0

0.5

0.5

4.5

1.35

1.35

Input voltage

V

IL

6.0

1.8

1.8

V

2.0

1.9

2.0

1.9

4.5

4.4

4.5

4.4

6.0

5.9

6.0

5.9

I

OH

= –20 µA

4.5

4.18

4.31

4.31

I

OH

= –2 mA

V

OH

6.0

5.68

5.80

5.63

V

V

IN

= V

IL

I

OH

= –2.6

mA

2.0

0.0

0.1

0.1

4.5

0.0

0.1

0.1

6.0

0.0

0.1

0.1

I

OL

= 20 µA

4.5

0.17

0.26

0.33

I

OL

= 2 mA

Output voltage

V

OL

6.0

0.18

0.26

0.33

V

V

IN

= V

IH

I

OL

= 2.6 mA

Input current

I

IN

6.0

±0.1

±1.0

µA

V

IN

= V

CC

or GND

Operating
current

I

CC

6.0

1.0

10.0

V

IN

= V

CC

or GND

Advertising