5(029$/ 2) '(%5,6 RU 6227 '(326,7
Allow the appliance to cool for two to three hours before removing all of the coals and ceramic blocks for
cleaning purposes. Once all the ceramics are removed from the fire bed check that no debris is located in the
burner slots (both front & rear). If any debris is present it may easily be removed by using a small piece of thin
cardboard to ease out any foreign matter. Be sure to remove the cardboard after use.

Cleaning should be carried

out in a well-ventilated area or in the open air, by gently brushing with the pieces held away from your face so
that you avoid inhaling the dust. We do not recommend the use of a normal domestic vacuum cleaner, which
may blow dust back into the air.

6(77,1* 83 7+( &2$/ %(' (See the identification sheet figure 13)
Components
2 burner inserts.

12 Large Coals.

Coal support shelves (L&R hand).

5 Medium Coals.

Artificial coal front

2 Triangular Coals

Place the left and right coal support shelves with the rebate on the underside, over the rear flange of the support
channel. Place the two shaped burner inserts into the channel between the front and rear ports of burner. Locate
the fibre artificial coal front on the shelf above the fascia panel. Figure 7.

&2$/ /$<287
First Layer. Position 4 large coals with their rear edge on the burner inserts. Place 3 large coals at the rear of the
coal support shelf and lay 2 further at the sides of the shelf. These coals are placed on their edge. 3 more large
coals are placed on the coal support shelf to complete the first layer. See figure 8.

Second Layer. Two triangular coals are placed one either side ensuring that they rest against the side and
straddle the gap between the front and second row large coal. Position the remaining 5 medium coals in the
positions shown in figure 9.

To obtain the best visual appearance it may be necessary to make slight adjustments to the position of the coals.

NOTE: Additional coals must not be used.

If any of the coals or the coal bed becomes damaged, lost or

broken, replacements must be obtained before the appliance is used.

9(17,/$7,21
Purpose built ventilation is required for this appliance with a minimal cross sectional area of 100 sq. cms and
should be checked regularly to ensure that it is free from obstruction. It must be fitted in accordance with the
rules in force.

&/($5$1&( 72 6+(/9(6
Minimum clearances to underside of a 150mm (6ins) combustible shelf from the top of the fire opening must be
228mm (9ins). Add 12.5mm (1/2in) to this clearance for every 25mm (1in) increased depth of shelf.

&/($5$1&( 72 6,'(6
Minimum Clearance required to any combustible material to the side of the appliance must be 150mm (6in)