2 camera output timing charts, Video out lval dval, Fval – Ricoh Gig# Vision VGA Monochrome CCD Camera FV-G030B1 User Manual

Page 7: Video out fval, Lval

Advertising
background image



7/38

FV-G030B1
User’s Guide Rev. 1.02

2 Camera Output Timing Charts

2.1

Horizontal Timing

1 CLK = 27.1605 nseconds















2.2

Vertical Timing

2.2.1

Full Scanning

1 H = 21.1852 µseconds, 89.91172 Hz












132 CLK

648 CLK

Video out

LVAL

DVAL

Horizontal blanking

780 CLK

One horizontal (1H)

648 CLK

132 CLK

132 CLK

Video output

132 CLK

94 CLK

39

CLK

FVAL

31H

494H

Video out

FVAL

Vertical blanking

525H

One vertical (1V)

494H

31H

31H

Video output

1

2

4

9

3

4

9

4

31H

LVAL

Advertising