14. Troubleshooting guide

• Aged fuel is one of major causes of

engine starting failure. Before storing
the unit, empty the fuel tank and run
the engine until it uses all the fuel left in
the fuel line and the carburetor. Store
the unit indoor taking necessary
measures for rust prevention.

12. Storage

13. Disposal

• When disposing your machine, fuel or

oil for the machine, be sure to allow
your local regulations.

Case 1. Starting failure

Make sure the icing prevention system is not
working.

WARNING

Check fuel for water

or substandard mix-

ture.

Check for engine

flooding.

Check the spark.

Replace with proper
fuel.

Remove and dry the
spark plug.
Then pull the starter
again with no choke.

Replace with a new
plug.

Case 2. Lack of power/Poor acceleration/ Rough

idling

Case 3. Oil does not come out

When your unit seems to need further service, please
consult with our service shop in your area.

➜➜

Check fuel for water

or substandard mix-

ture.

Check air filter and

fuel filter for clogging.

Check carburetor

for inadequate ad-

justment.

Replace with proper
fuel.

Clean.

Readjust speed needles.

Check muffler and

cylinder (exhaust port).

Wipe away carbon
buildup.

Check oil for sub-

standard quality.

Check oil passage

and ports for clog-

ging.

Replace.

Clean.