Caution – Renesas Emulation Pod M30830T-EPB User Manual

Page 39

Advertising
background image

( 37 / 72 )

(3) Connecting 100-pin 0.65-mm-pitch Foot Pattern (Part 2)

Figure 3.13 shows how to connect the emulation probe to the 100-pin 0.65-mm-pitch foot pattern on
the target system with the M3T-DIRECT100S (separately available), and here following is its
procedure. For details on the M3T-100LCC-DMS and M3T-DIRECT100S, refer to each instruction
manual.

(1) Attach the M3T-DIRECT100S to the target system.

For details on how to attach the M3T-DIRECT100S to the target system, see the instruction
manual of the M3T-DIRECT100S.

(2) Attach the M3T-100LCC-DMS to the M3T-DIRECT100S.
(3) Attach the M30800T-PTC to the M30830T-EPB.
(4) Attach the M30800T-PTC to the M3T-100LCC-DMS.

Figure 3.13 Connecting the emulation probe and 100-pin 0.65-mm-pitch foot pattern (2/3)

CAUTION

Notes on Connecting the Target System:

• Take care not to attach the converter board in a wrong direction. It may cause a fatal

damage to the emulator.

• The small connectors of the M3T-100LCC-DMS and M3T-DIRECT100S are

guaranteed for only 20 insertion/removal iterations.

• The small connectors of the M30800T-PTC are guaranteed for only 50 insertion/

removal iterations.

Advertising