DIMENSIONAL INFORMATION

APPROX.

MODEL

SHIPPING

NUMBER

UNITS

A

B

C

D

E

F

G

H

WEIGHT

STID30

inches

22

35-3/4

27-3/4

18-1/2

11-3/4

6-1/2

4-1/2

N/A

180 lbs

STID40

inches

22

42-3/4

34-3/4

31-1/2

16-3/4

6-1/2

4-1/2

N/A

226 lbs

STID50

inches

22

48-3/4

39-3/4

31-1/2

16-3/4

6-1/2

4-1/2

N/A

231 lbs.

STID80

inches

24

64-1/8

57-1/8

33

19-1/4

8

5

5

297 lbs.

STID120

inches

28

65-1/4

57-3/4

33-3/4

16-1/4

8-3/4

5

6-1/2

397 lbs.

Rheem Water Heating • 101 Bell Road, Montgomery, Alabama 36117-4305 • www.rheem.com

P R I N T E D I N U . S . A

0 5 / 0 8 W P

F O R M N O . R R 1 0 2 C - 3 I D

In keeping with its policy of continuous progress and product improvement, Rheem-Ruud reserves the right to make changes without notice.

Indirect Coil Tank continued.

STID80 & STID120

FIRST HOUR RATING (gal) @ Coil Output (Btu/hr)

TANK

FIRST

HEAT SOURCE

MODEL

CAPACITY

DRAW

FRICTION LOSS*

180°F,

180°F,

180°F,

200°F,

200°F,

200°F,

NUMBER

(GAL)

(GAL)

(FT. W.C.)

8 GPM**

10 GPM**

12 GPM**

8 GPM**

10 GPM**

12 GPM**

STID30

30

25

2

110 @ 55,000

114 @ 57,000

117 @ 59,000

132 @ 69,000

136 @ 71,000

139 @ 73,000

STID40

38

33

3

153 @ 77,000

165 @ 84,000

177 @ 92,000

183 @ 96,000

195 @ 104,000

207 @ 111,000

STID50

45

40

3

160 @ 77,000

172 @ 84,000

184 @ 92,000

190 @ 96,000

202 @ 104,000

214 @ 111,000

STID80

75

70

5

200@83,000

212 @ 91,000

224 @ 98,000

233 @ 104,000

245 @ 112,000

257 @ 119,000

STID120

110

102

5

232@83,000

244 @ 91,000

256 @ 98,000

265 @ 104,000

277 @ 112,000

289 @ 119,000

All data obtained through testing in accordance with GAMA INDIRECT-FIRED WATER HEATERS TESTING STANDARD IWH-TS-1_MARCH 2003

* At 8 GPM

**Coil Input (temperature, flow rate). Ratings based on 77°F rise with 58°F inlet potable water.

Note: First Hour Rating = First Dray + Continuous Draw

Warning: Installation should be in accordance with all national and/or local codes.

In the absence of local codes, refer to NFPA 54 or ANSI Z.21.10.1.

Caution: The recommended maximum hot water temperature setting for normal residential use is 120°F. Rheem recommends a tempering
valve or anti-scald valve be installed and used according to the manufacturer’s directions to prevent scalding.

Pressures (all): Test pressure, 300 psi; working pressure, 150 psi

Standard Voltage (all): 120V, 60 Hz, 1P

T&P valve installed

STID30, STID40

& STID50

G

H

A

E

F

D

C

B

Cold Inlet, 1" NPT

Hot Outlet,
1-1/2" NPT

Anode Rod

Anode

Rod

T&P Relief Valve

From Boiler,
1" NPT

To Boiler,
1"NPT

Drain Valve

Aquastat

G

Cold Inlet,
3/4" NPT

Hot Outlet/
Anode Rod,
3/4" NPT

Anode Rod

Aquastat

T&P Relief Valve

From Boiler, 1" NPT

To Boiler,
1" NPT

Drain Valve

F

D

C

E

B

A

WATER HEATERS

Limited Warranty

This product features a six year limited warranty against tank leaks when installed in
residential applications and three year limited warranty against tank leaks when
installed in non-residential applications. Please refer to the Warranty Information
document for complete warranty information.

Advertising
This manual is related to the following products:

45, 30, 38, 75