Roberts Gorden Vantage twin Fire Unitary Infrared Heater TF-250 User Manual

Page 58

Advertising
background image

TF-S

ERIES

I

NSTALLATION

, O

PERATION

AND

S

ERVICE

M

ANUAL

52

Gas Line

Check for gas leaks.

See Page 44, Section 10.

Burner Observation
Window

Make sure it is clean and free of cracks or holes.

Clean and replace as required.

Blower Scroll, Wheel and
Motor

Compressed air or a vacuum cleaner may be used to clean dust and dirt.

Burner Cup and Orifice

Clear of obstructions (even spider webs will cause problems).

Carefully remove any dust and debris from the burner.

Electrodes

Replace if there are cracked ceramics, excessive carbon residue, or erosion

of the electrodes. The electrode gap should be 1/8" (3.2 mm).

Thermostat

There should be no exposed wire or damage to the thermostat.

See Page 46, Section 11.

Suspension Points

Make sure the heater is hanging securely. Look for signs of wear on the chain
or ceiling.

See Page 17, Figure 14.

Decorative and Protective
Grille (optional)

The grille must be securely attached.

Check that the side reflector extensions are installed correctly and secured in
place if necessary (Decorative grille only).

See Page 34, Section 8.5 and Page 36, Section 8.6

Make sure shield is installed correctly and secured in place if necessary.
(Decorative grille only.)

See Page 35, Section 8.5.2.

Lower Clearance Shield
(optional)

The lower shield must be securely attached. Inspect shield support straps
and lower clearance shield anchor points.

Make sure shield is installed correctly and secured in place if necessary.

See Page 34, Section 8.4.

Wall Tag

If wall tag is present, make sure it is legible and accurate. Please contact
Roberts-Gordon LLC or your ROBERTS GORDON

®

independent distributor, if

you need a wall tag.

See Page 4, Section 2.1.

Safety Labels

Product safety signs or labels should be replaced by the product user when
they are no longer legible. Please contact Roberts-Gordon LLC or your ROB-
ERTS GORDON

®

independent distributor to obtain replacement signs or

labels.

See Page 2, Figure 1 through Page 3, Figure 2.

Advertising