Installation, Standard flush door – Regency P33R-LP2 User Manual

Page 23

Advertising
background image

Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace

23

Diagram 1

Diagram 3

STANDARD FLUSH

DOOR

The standard flush door comes with a black
frame. To install the frame, simply hook the top
door flange onto the top of the unit and swing
the door towards the unit, diagram 1. Be careful
that the glass gasket does not roll up; there
must be a gap between the gasket and the door
lip to ensure that the door sits securely on the
unit. Diagram 2.

Diagram 2

INSTALLATION

5th Grate Tab

6) Place the bottom left front edge of Log

D) 02-58 against the left edge of the burner
tray and rest the log on the cutout on Log
C) 02-60.

7) Position Log E) 02-59 across the cutouts in

Logs B) 02-61 and C) 02-60. The notch in
the bottom right end fitting against the 5th
grate tab.

8) Place the embers on the front of the burner

tray in the places shown on the photo.

Place embers in these 3 locations

on the burner tray.

D) 02-58

E) 02-59

A) 02-57

B) 02-61

C) 02-60

A) 02-57

B) 02-61

C)102-60

D) 02-58

C) 02-60

A) 02-57

B) 02-61

C) 02-60

B) 02-61

E) 02-59

Cutout

9) Test fire to ensure proper light off (make

sure flame flows smoothly from one end of
burner to the other). If there is any flame
hesitation, check that area for any block-
age of the burner ports.

10) Install flush glass and bay glass (if used) as

per instructions in this manual.

D) 02-58

A) 02-57

C) 02-60

B) 02-61

E) 02-59

Use the hook to pull the spring out until you can
put the hook into the slot on the bottom door
bracket. Repeat for 2nd spring. See diagram 3.

To remove the flush door, reverse the above
steps.

Optional Flush Trim

Attach the round magnets to the back of the top
trim piece and to the bottom trim piece, then
attach trim to the top and bottom of Flush door.

Advertising
This manual is related to the following products: