63 – – 62 – symptom diagnosis remedy, Symptom diagnosis remedy – Rockford Fosgate RFX8220 User Manual

Page 33

Advertising
background image

– 63 –

– 62 –

SYMPTOM

DIAGNOSIS

REMEDY

ERROR 6

(Transverse Error)

Transverse motor or
switch is defective.
Traverse area
damaged

Check CD mechanism motor,
switch and transverse area.

SYMPTOM

DIAGNOSIS

REMEDY

Disc will not load
into Source Unit

(also see error codes)

Voltage applied to Red
and Yellow wires is not
between 10.8 and 16
volts or there is no
voltage present

Check battery, fuses and
connections and repair or replace
as necessary. If voltage is above
+16 volts, have the electrical
system inspected by an autho-
rized car service center

Disc will not eject

(also see error codes)

Voltage applied to
Yellow wire is not
between 10.8 and 16
volts or there is no
voltage present

Check battery, fuses and
connections and repair or replace
as necessary. If voltage is above
+16 volts, have the electrical
system inspected by an autho-
rized car service center

ERROR 1

(Initialize Error)

No initialization

Press the reset button

Mechanism is jammed
and loading motor (or
driving circuit) is
defective

Repair the mechanism and
loading motor (or driving circuit)

ERROR 3

(Loading Error)

Foreign objects are
preventing the disc
from loading

Check CDP mechanism load area
by removing faceplate and repair
as necessary

Loading area in
mechanism and load-
ing motor (or driving
circuit) is defective

Repair the mechanism and load-
ing motor (or driving circuit)

ERROR 4

(Eject Error)

Foreign objects are
preventing the disc
from ejecting

Check CDP mechanism eject area
by removing faceplate and repair
as necessary

Ejecting area in mech-
anism and ejecting
motor (or driving cir-
cuit) is defective

Repair the mechanism and load-
ing motor (or driving circuit)

ERROR 9

(TOC Error)

Disc is warped
cracked or severely
damaged

Put in a different disc!

The laser pickup is
defective

Have a service center
repair the laser pickup

Servo unit in CDP
mechanism is not
operating properly

Check the servo circuit area and
repair as necessary

CD skips
excessively

Source unit mounted
at an incorrect angle

Check mounting angle of source
unit (mount within ±20˚ from hor-
izontal) and repair as necessary

Source unit not
secured properly
(Standard Mount)

Check tightness of installation
sleeve and backstrap and repair or
replace as necessary

Source unit not
secured properly
(ISO Mount)

Check tightness of mounting
screws and repair or replace as
necessary

Radiated Noises

No RF suppression
of blower motors

Connect filter cap (Radio Shack
#272-1085) in-line on B+ as close
to blower motor as possible

No RF suppression
of switches

Connect a .1µf – .01µf non-polarized
capacitor across switch contacts

ERROR 7

(Servo Error)

Excessive dirt or dust
on disc

Clean disc to remove dirt or dust
as necessary

Disc is warped
cracked or severely
damaged

Put in a different disc!

Excessive scratches
on disk

Put in a different disc!

Advertising
This manual is related to the following products: