Russound MCA-C5 User Manual

Page 17

Advertising
background image

17

Russound MCA-C5 User and Installation Manual

Controller / Keypad Connection

The MDK-C5 keypad is designed for use with the C-Series controllers, and

connects to a keypad port near the top left on the rear of the controller. These

RJ-45 ports support MDK-C5 keypads (and up to two UNO-TS2 touchscreens

per controller).

The eight keypad ports correspond to the eight zones supported by the

MCA-C5. When a connected keypad is powered on, the zone becomes

active and the corresponding zone LED lights up on the front of the MCA-C5

controller.

Connections are made using CAT-5e with RJ-45 connectors using T568A wire

configuration. For a clean installation when wiring from a keypad port use

a CAT-5e patch cable to connect from the keypad port to a RJ-45 wall plate

(optional). Using the same T568A RJ-45 wiring configuration, use CAT-5e cable

from the wall plate to the keypad. Maximum CAT-5e cable length is 250 feet

between the controller and the keypad. The OS Update jumper should be in

the RUN position on the lower two pins.

If more keypads are desired for a zone, use an optional SA-ZX3 keypad

splitter with a Russound 1201A (12VDC 1A) power supply at the controller end.

All keypads on an SA-ZX3 control the same zone. More detailed information

regarding SA-ZX3 installation and operation can be found in its installation

manual.

Keypad connection to the MCA-C5

MDK-C5

MCA-C5 Controller

CAT-5e Cables

MDK-C5

CONTROLLER / KEYpAd CONNECTION

Advertising