Rinnai R75LSI (VA2528FFUD) User Manual

Page 2

Advertising
background image

3.6 (91)

14 (355.6)

9.6 (244.5)

22

.9

(

5

82)

2

5

.5 (

6

48

.2

)

4.3 (110)

1.1 (27)

3.5 (89)

3.9 (99)

2.8 (70)

R75LSi (VA2528FFUD)

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us

Water Temperature Control

Controller





Controller Cable

Safety Devices


Clearances from Combustibles
(suitable for closet, attic, and
crawl space installations)

Clearances from Non-combustibles



Min. / Max. Gas Supply Pressure


Manifold Gas Pressure (inches W.C.)


NOx

Warranty

Simulation feed forward and feedback

MC-91-1US (part of the front panel)
Deluxe controller: MC-100V-1US (optional)
Bathroom controller: BC-100V-1US (optional)
Wireless controller: MC-502RC-1US-MS (optional)
MCC-91-1US (for commercial applications)

Non-polarized two-core cable, minimum 22 AWG

• Flame failure - Flame Rod

• Boiling protection

• Combustion fan rpm check

• Over current - glass fuse (3 amp)
• Top of heater - 6 inches

• Front of heater - 6 inches

• Sides of heater - 2 inches
• Top of heater - 2 inches

• Front of heater - 6 inches

• Sides of heater - 1/2 inch

Natural Gas: min 5” W.C.

max 10.5” W.C.

Propane Gas: min 8” W.C.

max 13.5” W.C.

Natural Gas: high fire 2.7” W.C.

low fire 0.52” W.C.

Propane Gas: high fire 4.4” W.C.

low fire 0.92” W.C.

Meets California and Texas NOx Emission Rules

Heat exchanger: 12 years* for residential and 5 years* for
commercial and hydronic applications; (10 years* if used with the
Rinnai Hydronic Air Handler); all other parts 5 years*; labor 1 year;
(* 3 years if used as a circulating water heater within a circulation
loop, when the water heater is in series with a circulation system
and all circulating water flows through the water heater)

DIMENSIONS

Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior
notice. Local, state, provincial and federal codes must be adhered to prior to installation.

• Remaining flame (OHS)

• Thermal fuse

• Automatic frost protection

• Back of heater - 0 inches

• Bottom of heater - 12 inches

• From vent pipe - 0 inches
• Back of heater - 0 inches

• Bottom of heater - 12 inches

• From vent pipe - 0 inches

The wall bracket is adjustable to allow
an additional 1.57 inches (40 mm).

in (mm)

WEIGHT: 50 LBS (23 KG)