Rikaline, Appendix c developer’s setting, C.1 $pnmrx100, set serial port mode – Rikaline GPS-24/24A User Manual

Page 15: C.2 $pnmrx101, navigation initialization

Advertising
background image

GPS Receiver Board

GPS-24 / 24A Operating Manual

Rikaline

Specifications subject to change without prior notice

Rikaline

International Corp.

14F, 171, ChengGong Rd, Sanchong CityTaipei 241, Taiwan

Tel: ++886 2 8973 1899 Fax: ++886 2 8973 1896 E-Mail:

[email protected]

Web: www.rikaline.com.tw

Appendix C Developer’s Setting

For all $PNMRX messages, it is possible to configure an alternative string to replace the NMRX part,

the node always responds to the $PNMRX strings and can be configured to generate and respond to
the alternative string.


C.1 $PNMRX100, Set serial port mode

This message is sent to control the serial communications port parameters. The $PNMRX100

message format is shown below.

Field Format

Min
chars

Max
chars

Notes

Message ID

$PNMRX100

6

6

PNMRX100 protocol header.

Protocol Char

1

1

0

NMEA

mode

1 NemeriX Binary Mode (under dev)

Baud

Int

4

6

1200 / 2400 / 4800 / 9600 / 19200 / 38400 /
57600.

Parity Char 1

1

0.

None.

1. Odd.
2. Even.

Checksum

*xx

(0) 3

3

2 digits.

Message
terminator

<CR> <LF>

2

2

ASCII 13, ASCII 10.

Examples:
$PNMRX100,0,4800,0*xx: sets the UART baud rate to 4800 bps and no parity.


C.2 $PNMRX101, Navigation Initialization

This message is sent to initialize navigation parameters to speed up initial acquisition time. The

$PNMRX101 message format is shown below.

Field Format

Min

chars

Max

chars

Notes

Message ID

$PNMRX101 6

8

PNMRX101 protocol header.

ECEF_X

Int

(-)7

(-)7

Signed ECEF x co-ordinate in meters

ECEF_Y

Int

(-)7

(-)7

Signed ECEF y co-ordinate in meters

ECEF_Z

Int

(-)7

(-)7

Signed ECEF z co-ordinate in meters

Clock offset

Int

(0) 1

6

Clock offset of GPS receiver, in [Hz x 100] wrt L1.
This changes the clock bias stored in the settings
not the actual clock bias used by the system. A cold
start is necessary, in order to use this value.

Time of week

Int

1

6

Offset from start of week in seconds

Week number Int

1

4

GPS week number

Channel count Int

1

2

Maximum number of TM to be used. Min 12, max 16.

Checksum

*xx

(0) 3

3

2 digits.

Message
terminator

<CR> <LF>

2

2

ASCII 13, ASCII 10.

Note: 1// If used, all three X,Y, and Z components of the ECEF position must be provided, otherwise the

message is declared invalid as a whole

2// Modifying the ECEF coordinates triggers a software system reset after successful execution of the

message

Examples:
$PNMRX101,,,,,,,,8,*xx:

Executes a factory reset

$PNMRX101,-742507,-5462738, 3196706,*xx: Sets the receiver position to ECEF (,) and executes a

software reset

$PNMRX101, 4,*xx:

Sets the fix procedure mode the cold start. This will be
valid after each reset, until this value is changed.

Advertising