4 no main power, Measures causes – Royal Sovereign RSL-2701 User Manual

Page 11

Advertising
background image

3. Film is jammed on the rollers.

1) First press reverse button.

2) Pull jammed film slowly to the back of the machine.

3) If you feel film is jammed again, stop pressing reverse button.

4) press run button, and then pull jammed film to the back of the machine.

4. Main PCB is defective

Replace Main PCB with new one according to How to replace Main PCB

only when all of the above mentioned Emergency switch, Frame paper guide,

Safety cover switch, motor wire connectors, main motor and film are normal.

5. Replace Motor with new one according to How to replace the Motor.

2.4 No Main Power

1. Main power wire is not connected with Main Switch

2. Main fuse is disconnected.(except RSL-380)

3. Wire-AC IN is not connected with Main PCB.(except RSL-380)

4. Transformer is defective.

Before troubleshooting, be sure to disassemble the Right cover ,

the Left cover and the FRAME Rear.

Refer to how to replace each component for the

disassembly of them.

1. Main power wire is not connected with Main Switch.

1) Check if the Main power wires are connected correctly.

<RSL-2701/2701U>

<RSL-380>

9

MEASURES

CAUSES

MAIN SWITCH

MAIN SWITCH

connecting part

Advertising
This manual is related to the following products: