Overall performance, Protection, Environment – Rosewill RV-480-2-FRB User Manual

Page 7: Safety standards, Emi standard, Hi-pot testing, Insulation resistance, Reliability

Advertising
background image

POWER SUPPLY Value series

User Manual

6

© 2004-2006 Rosewill Inc. All rights reserved by Rosewill

Overall Performance

Effi ciency

: 70% at typical full load and normal input voltage

Hold-Up Time

: 17ms at full load and normal input voltage

Switching Frequency : 60HZ at normal input.
Stability

: ±10%, for 24 hours after warm up.

Protection

Over Load Protection :
150% over load protection
Over voltage protection :
Main output over 20% protection
Short Circuit Protection :
All output equipped with short circuit protection

Environment

Operation Temperature : 0°c to +40°c
Storage Temperature : -40°c to +70°c
Operating Humidity : 10% to 90% RH
Storage Humidity : 10% to 90% RH

Safety standards

TUV/CE/CB/FCC/UL

EMI Standard

Meet with FCC class B and CISPR-22B

HI-POT Testing

Input to ground : 15KVac/10mA 3 second

Input to output : 15KVac/10mA 3 second

Insulation resistance

Input to ground : Min 50M
Input to output : Min 50M

Reliability

MTBF : 50000 hours at 25°c ambient temperature

Advertising