START UP

Refer to the Start Up procedure outlined in the
Lectra/San MC Manual. The following instructions
are supplementary to those instructions.

Note: If utilizing a VacuFlush toilet see Application
Note (L286).

1. Check plumbing and electrical connections.

2. Turn on water supply.

3. Check for leaks.

4. Fill tank with solar salt.

No adjustments are necessary with this system.

Float Valve

Assembly

(31-312)

Fig. #5 Four Gallon Salt Feed System with Pump Exploded Parts

Tank with Lid

(31-311)

Salt Feed Pump

32-300 (12 VDC)
33-300 (24 VDC)

Mounting Adapter

(31-315)

Inlet Filter Screen

(31-322)

O- Ring

(1203B3)

O-Ring

(1203B3)

Overflow Grommet

(31-317)

Elbow

(31-318)

Outlet

Grommet

(31-316)

Overflow Hose

(Not Supplied)

Check Valve

(31-326)

Tubing

(31-319)

Tank Lid Adapter

(31-325)

Salt Feed Pump

(32-300 12V
33-300 24V)

Salt Feed

Lectra/San MC

Circuit Board

Black

Red

U15

U14

Fig. #4 Wiring Diagram for Four Gallon Salt Feed

System with Pump

VacuFlush

®

is a registered trademark of Sealand Technology, Inc.

Install here