- 16 -

ITEM U.U.T.

SETTING

ADJUST

POINT

MEASUREMENT

TX Power

Set radio to Fr Pool 2, CH 19 AM TX mode.
Connect “short PCB” to TP7, TP8 and TP9.
Connect RF Power Meter to antenna jack.
Set RF Power Fully Clockwise.

L40,L42,L43,
L44


L40,L42


Power MAX.
Spurious emission
Min.

Balance Power
between CH 1 and
CH 40.

AM TX Power Set radio to Fr Pool 2, CH 19 AM TX mode.

Modulation off.

VR14 10W

(RCI-6300F

HP)

50W (RCI-6300F TB)

RF Power
Meter

Set radio to Fr Pool 2, CH 19 AM TX mode.
Set SWR/S-RF switch to S/RF position.
Modulation off.

VR9

Adjust RF Power
meter needle until it is
in-between the green
and red bar on PWR
scale.

AM
Modulation

Set radio to Fr Pool 2, CH 19 AM TX mode.
Set Mic Gain Fully Clockwise.
AF signal 30 mV, 1 KHz to microphone.

VR16 90%

FM Deviation

Set radio to Fr Pool 2, CH 19 FM TX mode.
Set Mic Gain Fully Clockwise.
AF signal 30 mV, 1 KHz to microphone.

VR5 4KHz

Frequency
Counter Adjust

Set radio to Fr Pool 2, CH 19 AM RX mode.
Set DIM/BRT switch to BRT position.

VC1 on
frequency
counter

Display should be
28.9150


















4.1.3 RECEIVER ALIGNMENT