Ault codes, Ip switch settings – Rinnai RHFE-1510F User Manual

Page 14

Advertising
background image

F

ault Codes

D

ip Switch Settings

27

28

Central Timer

Control

Stand Alone

Control

off on

off on

1

2

3

4

1 Computer

Programming

2 Computer

Programming

3

Central Control System

4 Emergency

Cut

Off

If controlled by a central timer, dip switch 3
must be in the ON position.

To use a time clock you will also require a
transformer and sub PCB available from Rinnai.

When a time clock is used the appliance On/Off
button will not operate.

If Emergency cutoff loses signal unit will stop.

Emergency Cut Off can not be used with

Central Control System.

HI

Overheat
Switch

Blocked Flue Terminal

Blocked Air Filter

Power Failure

Warm Air Obstruction

Gas Type

Gas Pressure

Convection Fan coil resistance

PCB voltage to Convection Fan

PCB voltage to Overheat Circuit

Thermal Fuse Resistance

Overheat Switch Resistance

CI

Room Temp
Sensor Faulty

Room Temp Thermistor Resistance

C2

Overheat Temp
Sensor Faulty

Overheat Thermistor Resistance

H6

Overheat

Thermal Fuse

dI Sparker

Failure

PCB

Sparker input voltage

Spark Gap

bI & Com-
bustion Lamp

No Ignition

Flame Rod carboned up

PCB

Blocked burner ports

Blocked Flue Terminal

Gas Type

Combustion Fan

Gas Pressure

EO

Communication
Error (Ghost
Flame)

PCB

Flame Sensor
Sparker

b3 + Com-
bustion Lamp

Flame Failure

Physical Blockages
Flame Rod

n2

Air Proving
Device

Blocked Flue

Faulty PCB

Combustion Fan

Kinked/disconnected air tube

Heat Exchanger Blocked

Air Proving Senser

n1

On/Off Button
Faulty

Check On/Off switch

sub PCB
PCB