Regency P40-NG1 User Manual

Gas fireplaces, P40 direct vent gas fireplace, Gh i

Advertising
background image

P40 Direct Vent Gas Fireplace

Model

P40-NG1

P40-LP1

Fuel Type

Natural Gas

Propane

Minimum Supply Pressure

5” W.C. (1.25 kPa)

12” W.C. (3.00 kPa)

Manifold Pressure - High

3.5” W.C. (0.87 kPa)

10” W.C. (2.49 kPa)

Manifold Pressure - Low

1.6” W.C. (0.39 kPa)

3.6” W.C. (0.89 kPa)

Orifi ce Size - Front Burner

#44 DMS

#55 DMS

Orifi ce Size - Rear Burner

#35 DMS

#53 DMS

Minimum Input

13,000 BTU/h (3.81 kW)

12,000 BTU/h (3.51 kW)

Maximum Input

45,000 BTU/h (13.19 kW)

43,000 BTU/h (12.60 kW)

Vent Sizing

5” Inner / 8” Outer

5” Inner / 8” Outer

Approved Venting Systems

Flex Vent Systems:

FPI AstroCap™ Flex Vent

Rigid Pipe Vent Systems:

Simpson Dura-Vent® Direct Vent GS
Selkirk Direct-Temp

A

B

A

D

C

F

E

Unit Dimensions

Description

P40

A

Front Face Width

40” (1016mm)

B

Rear Firebox Width

33-7/16” (889mm)

C

Front Face Height

34” (864mm)

D

Height w/ Standoff

42-1/2” (1080mm)

E

Unit Depth

20-1/16” (508mm)

F

Height to Vent

35-1/4” (826mm)

Framing Dimensions Description

P40

G

Framing Width

40-1/2” (1029mm)

H

***

Framing Height

***

42-1/2” (1080mm)

***

+ Hearth

I

Framing Depth

20-1/16” (508mm)

J

Corner Wall Length

50-5/8” (1286mm)

K

Corner Facing Wall Width

71-5/8” (1524mm)

L

Minimum Height to Combustibles

51-7/8” (1318mm)

M

Vent Centerline Height

45-3/8” (1153mm)

N

Non-Combustible Facing Height

10-1/4” (260mm)

O

Gas Connection Height

1-1/2” (38mm)

P

Gas Connection Inset

4-3/4” (121mm)

Q

Gas Connection Width

3-1/4” (102mm)

***

Important: Framing height requires consideration of the hearth

depth. Dimension H = H + the thickness of installed hearth.

G

H

I

K

J

L

P Q

O

M

11" (279mm)

dia. Hole through

wall Vent.

Opening for gas

connection

Top Header
(non-combustible)

Drywall

(or other

facing)

N

Top Header

(non-combustible)

Non-Combustible Facing

P40 Gas Fireplace

Please refer to Page 11 (Exterior Vent Terminations)

for additional guidelines on vent locations.

Unit requires

120V to operate. See

“Wiring Diagram,” on page 17,

for more details. Receptacle is

included with manual.

45

June 2007 Regency Product Specifi cations Book

Gas Fireplaces

Gas Fir

eplaces

Advertising
This manual is related to the following products: