Raypak Hydronic Heating Boiler 992BE-2342BE User Manual

Hi delta, Type h, 87% efficiency

Advertising
background image

Catalog No.: 2000.451E

Effective: 11-15-07

Replaces: 1-1-07

Job:

Engineer:

Contractor:

Prepared By:

Date:

Model:

Indoor/Outdoor:

MBTUH Input:

Š 100% Factory Fire Tested
Š Efficiency: 87%
Š Maximum Outlet Temperature: 230°F
Š Minimum Non-Condensing Inlet Temperature: 120°F
Š Thermal Shock Proof Heat Exchanger
Š Limited Twenty-Year Thermal Shock Warranty
Š Limited Ten-Year Closed-System Heat Exchanger

Warranty

Š Diagnostic Center with Fault History
Š PolyTuf Powder Coated Cabinet
Š No Combustible Floor Shield Required
Š Fan-Assisted
Š Patented Burner Security Blanket

Heat Exchanger
ƒ H

Stamp

ƒ Headers

Glass-Lined Cast Iron – Standard
Bronze – Option A-1

ƒ ASME Inspected and Stamped

160 PSIG Working Pressure

ƒ National Board Approved
ƒ Fin

Tubing

Copper – Standard
Cupro Nickel – Option A-3

ƒ ASME Steel Tube Sheet
ƒ Silicone High Temp. O-Rings
ƒ ASME Pressure Relief Valve

60 PSIG – Standard
PSIG – Optional

ƒ Temperature and Pressure Gauge
ƒ Water

Connections

Left – Standard
Right – Option A-6

Controls
ƒ 120V, 60Hz, 1

∅ Power Supply

ƒ 120/24V 60Hz Transformer
ƒ 100%

Shut-Off/Lockout

ƒ Hot Surface Ignition
ƒ Remote Flame Sensor
ƒ High Limit Control, Manual Reset
ƒ On/Off Power Switch
ƒ Manual

Shut-Off,

Front-Mounted

ƒ Flow

Switch

ƒ Blocked Vent Pressure Switch
ƒ Combustion Air Proving Switches
ƒ Economaster Pump Time Delay
ƒ Enable/Disable

Gas Train
ƒ Manual Gas Shut-Off Valve(s)
ƒ Gas

Pressure

Regulator

ƒ Safety Shut-Off Valve
ƒ Firing

Control

Valve

ƒ Low Gas Pressure Switch, Manual
ƒ Firing Mode

3-Stage (H8): Model 992BE
4-Stage (H9): Models 1262BE -

2342BE

ƒ Fuel

Natural Gas
Propane Gas
4” WC Gas Supply Pressure

G-20

ƒ Design Certified ANSI Z21.13/

CSA 4.9

Construction
ƒ Indoor/Outdoor

Construction

ƒ Enclosed Front Controls

Venting
ƒ Vent

Location

Top – Standard
Rear – Option D-14

ƒ Vent Termination Cap

Outdoor D-11
Indoor, Horizontal D-15
Indoor, Vertical (by others)

ƒ Combustion

Air

In-Line Filter Kit (TruSeal only)

D-17

Air Intake Elbow D-16

ƒ Extractor – Optional

By others
Not required

Burner
ƒ Ultra-Low NOx: Less than 30 PPM

Temperature Controls

B- TempTracker

Digital

Controller,

4-Stage

Y-241 Electronic Sequencer, 4-Stage
Y-281 Electronic Sequencer, 8-Stage

Options

C-6

Ignition Module, Manual Reset

D-21 TruSeal

®

Direct Vent

F-10 Low Water Cut-Off, Remote

Probe

I-1

High Limit Control, Auto Reset

P- Pump: HP, 120V, 1

∅,

60Hz
Water Hardness: GPG

Cast Iron

Bronze

Mounted

Loose

Front

Rear

P-26 Cold Water Start (See 2000.49)
S-2

High Gas Pressure Switch,
Manual

X-1

SureRack™ Kit

X-2

SureRack Add-on

Regulatory Agency Requirements

Hi Delta

®

- Type H

Hydronic Heating Boiler

Models 992BE-2342BE

87% Efficiency