Raypak 302BE-902BE User Manual

Hi delta, Type h, 87% efficiency

Advertising
background image

Catalog No.:

2000.441E

Effective: 11-15-07

Replaces: 1-1-07

Job:

Engineer:

Contractor:

Prepared By:

Date:

Model:

Indoor/Outdoor:

MBTUH Input:

Š 100% Factory Fire Tested
Š Efficiency: 87%
Š Maximum Outlet Temperature: 230°F
Š Minimum Non-Condensing Inlet Temperature: 120°F
Š Thermal Shock Proof Heat Exchanger
Š Limited Twenty-Year Thermal Shock Warranty
Š Limited Ten-Year Heat Exchanger Warranty
Š Diagnostic Center with Fault History
Š PolyTuf Powder Coated Cabinet
Š No Combustible Floor Shield Required
Š Fan-Assisted
Š Patented Burner Security Blanket

Heat Exchanger
ƒ H

Stamp

ƒ Headers

Glass-Lined Cast Iron – Standard
Bronze – Option A-1

ƒ ASME Inspected and Stamped

160 PSIG Working Pressure

ƒ National Board Approved
ƒ Fin

Tubing

Copper – Standard
Cupro Nickel – Option A-3

ƒ ASME Steel Tube Sheet
ƒ Silicone High Temp O-Rings
ƒ Pressure Relief Valve, ASME

45 PSIG – Standard on Models

302BE and 402BE

60 PSIG – Standard on Models

502BE-902BE

PSIG – Optional

ƒ Temperature and Pressure Gauge
ƒ Water

Connections

Left – Standard
Right – Option A-6

Controls
ƒ 120V, 60Hz, 1

∅ Power Supply

ƒ 120/24V 60Hz Transformer
ƒ 100%

Shutoff/Lockout

ƒ Hot Surface Ignition
ƒ Remote Flame Sensor
ƒ High Limit Control, Manual Reset
ƒ On/Off Power Switch
ƒ Manual

Shut-Off,

Front-Mounted

ƒ Flow

Switch

ƒ Blocked Vent Pressure Switch
ƒ Combustion Air Proving Switch
ƒ Economaster Pump Time Delay

Gas Train
ƒ Manual Gas Shut-Off Valve(s)
ƒ Gas

Pressure

Regulator

ƒ Safety Shut-Off Valve
ƒ Firing

Control

Valve

ƒ Firing Mode

On/Off (H4): Models 302BE

and 402BE

2-Stage (H3): Models 302BE -

902BE

ƒ Fuel

Natural Gas
Propane Gas
4” WC Gas Supply Pressure

G-20

ƒ Design Certified ANSI Z21.13/

CSA 4.9

Venting
ƒ Vent

Location

Top – Standard
Rear – Option D-14

ƒ Vent Termination Cap

Outdoor D-11
Indoor, Horizontal D-15
Indoor, Vertical (by others)

ƒ Combustion

Air

In-Line Filter Kit (Recommended

with Ducted-In Air Only) D-17

Air Intake Elbow D-16

ƒ Extractor - Optional

By Others
Not Required

Construction
ƒ Indoor/Outdoor

Construction

ƒ Enclosed Front Controls

Burner
ƒ Ultra-Low NOx: Less than 30 PPM

Temperature Controls

B-2

Tankstat, Single-Stage (100-200°F)

B-3

Tankstat, 2-Stage (100-200°F)

B-6

Aquastat, 2-Stage (100-200°F)

B- TempTracker

Digital

Controller,

2-Stage

B- TempTracker

Digital

Controller,

4-Stage

Y-241 Electronic Sequencer, 4-Stage
Y-281 Electronic Sequencer, 8-Stage

Options

C-6

Ignition Module, Manual Reset

D-21 TruSeal

®

Direct Vent

F-10 Low Water Cut-Off, Remote Probe
I-1

High Limit Control, Auto Reset

P- Pump: HP, 120V, 1

∅, 60Hz

Water Hardness: GPG

Cast Iron

Bronze

Mounted

Loose

Front

Rear

P-26 Cold Water Start (See 2000.48)
S-1

Low Gas Pressure Switch, Manual

S-2

High Gas Pressure Switch,
Manual

X-1

SureRack™ Kit

X-2

SureRack Add-on

Regulatory Agency Requirements

Hi Delta

®

- Type H

Hydronic Heating Boiler

Models 302BE-902BE

87% Efficiency