Raypak RAYTHERM 962-1826 User Manual

Raytherm, Type h, Hydronic heating boilers commercial

Advertising
background image

Catalog No.: 2000.24O

Effective: 04-15-10

Replaces: 12-01-07

Job:

Engineer:

Contractor:

Prepared By:

Date:

Model:

EFFICIENT


82% efficiency – highest of any atmospheric

boiler available today

THERMAL SHOCK PROOF


Twenty-year warranty against thermal shock damage

up to 150°F differential



Maximum operating temperature: 230°F

LIGHTWEIGHT


A floor load of 70 lbs./sq. ft. or less

HIGH RECOVERY


Cuts fuel costs substantially because the standby and

radiation losses normal to other boilers are eliminated

LOW WATER OPERATING TEMPERATURE


Operates with inlet water temperature as low as 105°F

without condensing

Heat Exchanger
ƒ

ASME Inspected and Stamped

160 PSIG

ƒ

National Board Listed

ƒ

Headers

Glass-lined Cast Iron – Standard
Bronze – Option A-1

ƒ

Finned

Tubing

Copper – Standard
Cupro Nickel – Option A-3

ƒ

ASME Steel Tube Sheet

ƒ

Silicone

O-Rings

ƒ

60 PSIG ASME Pressure Relief Valve

ƒ

Temperature and Pressure Gauge

ƒ

Water

Connections

Left Hand – Standard
Right Hand – Option A-6

ƒ

Flow

Configuration

Two-pass – Standard
Single-pass – Cast Iron Only

ƒ

Pump - Rear-mounted, 1/2 HP,

120 VAC, 1∅, 60 Hz – Optional

4.25” Impeller
4.7” Impeller

Controls
ƒ

120V, 60Hz, 1 Ph Power Supply

ƒ

120/24V

Transformer

ƒ

100% Pilot Shut-off/Lockout

ƒ

Electronic, Intermittent Ignition (IID)

Pilot

ƒ

High Limit Control, Manual Reset,

240°F

ƒ

On/Off

Switch

Controls (cont.)
ƒ

Flow

Switch

ƒ

Economaster Pump Time Delay

Gas Train
ƒ

Manual Main Gas Shut-off Cock

ƒ

Main Gas Pressure Regulator

ƒ

Redundant Safety Shut-off Valve

ƒ

Control Valve

ƒ

Firing

Mode

On/off (H4)
Two-stage Firing (H3)
Four-stage Firing (H9)
Mechanical Modulation,

110-170°F (H5)

Mechanical Modulation,

150-210°F (H1)

Motorized Modulation (H2)

ƒ

Fuel

Natural Gas
Propane Gas

ƒ

Design Certified ANSI Z21.13/CSA 4.9

Construction
ƒ

AB 1953 & VLA 193 Compliant

ƒ

Front

Controls

ƒ

Stainless Steel Burners

ƒ

Polytuf Powder Coat Finish

ƒ

Vent

Selection

Draft Diverter – Option D-10
Power Vent, Loose – Option D-2

ƒ

Base

(Optional)

Combustible Floor Shield –

Option J-1

Temperature Controllers

Note: H1 and H5 do not require a

controller

B-6 Two-stage
B-36 TempTracker Mod+ Hybrid
B-40 Motorized Modulation
B-41 Motorized Modulation,

Outdoor Reset

B- Four-stage

Digital

Y-241 Electronic Sequencer,

1-4 Stages

Y-281 Electronic Sequencer,

1-8 Stages

Remote Controller

By others:

Additional Safety Controls

F-9

Low Water Cut-off Probe

I-1

High Limit Control, Auto
Reset, 240°F

S-1

Low Gas Pressure Switch,
Manual

S-2

High Gas Pressure Switch,
Manual

Regulatory Agency Requirements








Raytherm

®

- Type H

Hydronic Heating Boilers

Commercial

Models 962-1826 (Indoor)

INDOOR

Advertising