Valve replacement, Maintenance – Regency L234-NG User Manual

Page 34

Advertising
background image

Regency

®

L234 Direct Vent Gas Insert

34

MAINTENANCE

MAINTENANCE

VALVE REPLACEMENT

1) Open the left and right side faceplate

panels.

2) Remove the bottom louver by pulling out.

3) Remove the glass door.

a) Pull off the left side spring hook that holds
the door in place. While holding the hook turn
it upside down and place it into the middle
opening on the top side mounting bracket.
Repeat for right side

.

b)

Swing the door out 45 degrees and lift up

and out.

7) Disconnect the gas connection to the

valve.

8) Disconnect the ignitor wire from the DC

Sparker.

9) Disconnect the valve wires from the DC

Sparker.

10) Unplug the 2 connectors from the valve.

DC Sparker Wires

4) Remove the logs.

5) Remove brick panels, if installed.

6) Remove the valve shield by undoing the 2

screws.

Valve Shield

Spring Hook

Top Mounting Bracket

Advertising