FPI U31-2 Gas Fireplace Insert

THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS

FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!

Conversion Kit from Natural Gas to Propane

Model #402-969 for: U31-NG2 Units

1) Turn the unit off and allow it to cool to room

temperature.

2) Unplug or disconnect power source to

stove.

3) Remove glass front (see manual).

4) Remove logs and brick panels (if in-

stalled).

5) Remove the Grate by removing the screws

on each side of the grate.

Remove the 2 screws holding

the grate in position.

Remove the 2 screws,

push Burner Tray to the left, and lift off.

6) Remove the Burner Tray by removing the

screws on each side of the tray. Push the
tray to the left and lift up.

7) Remove burner orifi ce with 1/2" wrench and

replace with the #52 orifi ce in the Kit.

Diagram 1

8) Remove regulator from valve and replace

with Propane regulator. See diagram 1.

Burner

Orifi ce

9) Pull off the pilot cap to expose the pilot

orifi ce.

10) Unscrew the pilot orifi ce with the allen key

and replace with the LP pilot orifi ce in the
kit.

11) Replace Burner Tray and reverse steps 5)

to 1).

12) Adjust the burner aeration setting to 1/8"

to 3/16" as required for the best fl ame pic-
ture.

INSTALLATION

GAS CONNECTION

3) Locate the center point where the vent will

pass through the chimney above the appli-
ance. Move the appliance into the exact
location where it is to be installed. Ensure
that the Insert is level.

4) The installer must provide a valve with a

plugged tapping, accessible for test gauge
connection, immediately upstream of the
gas supply connection to the appliance.

HIGH ELEVATION

This unit is approved in Canada for altitude 0 to
2000 ft. with the orifi ce supplied. For 0' - 4500'
use the optional fi eld conversion kit (Part #400-
970 for Natural Gas units and Part #400-971 for
Propane units). In USA refer to ANSI Z223.1-
1988, Appendix F, for re-sizing orifi ce.

DRAFT HOOD

CONNECTION

1) Attach the vent to the fl ue collar on the

detachable draft hood. The fl ue collar of
the appliance will fi t inside a standard vent
and may be fastened directly to the vent by
sheet metal screw. Diagram 1.

2) Before pushing the appliance into position

inside the fi replace, align the draft hood
with the guides on the insert top and push
forward. While pushing the unit back into
place keep pulling the draft hood forward
until the screw hole in the spill tube aligns

GAS CONNECTION WARNING:
Only persons licensed to work
with gas piping may make the
necessary gas connections to this
appliance.

1) If the appliance is to be installed into an

existing chimney system, thoroughly clean
the masonry or factory built fi replace.

2) The appliance is provided with an opening

on the left hand side of the control com-
partment. A 1/2" gas supply pipe must be
brought near this inlet hole. (See Diagram
3 on page 11).