Step 1: replacing existing thermostat, Important safety information warning, Old terminal new label description – Robertshaw 9420 User Manual

Page 2: Table 1

Advertising
background image

IMPORTANT SAFETY INFORMATION WARNING:

• Always turn off power at main fuse or circuit breaker panel before

installing, removing, cleaning, or servicing thermostat.

• Read all the information in this manual before installing this

thermostat.

• This is a 24 VAC low-voltage thermostat. Do not install on voltages

higher than 30 VAC.

• All wiring must conform to local and national building and electrical

codes and ordinances.

• Do not short (jumper) across terminals on the gas valve or at the

system control to test installation. This will damage the thermostat
and void the warranty.

• Do not connect ground to any terminal in this unit.

Step 1: Replacing Existing Thermostat

1. Turn off power to heating and cooling system.

2. Remove cover from old thermostat to expose wires (Figure 1).

3. Disconnect wires one at a time from existing terminals. Use enclosed labels

to mark existing wires. Refer to cross references in Table 1 if existing wiring
does not directly match the labels.

4. Remove existing thermostat base from wall.

Old Terminal

New Label

Description

R, V-VR or VR-R

R

24 VAC, Return

Y, Y1 or M

Y1

Compressor Relay (Stage 1)

O or R

O

Reversing Valve (Cool Active)

B

B

Reversing Valve (Heat Active)

F or G

G

Fan Control Relay

Y2

Y2

2nd Stage Cooling Circuit

W2 or W-U

W2

2nd Stage Heating Control

C, X or B

C

24 VAC, Transformer Common Side

L or X

L

System Monitor

E

E

Emergency Heating Circuit

NOTE: THIS THERMOSTAT REQUIRES A 24V COMMON WIRE FOR PROPER OPERATION.

Table 1

2

Figure 1

!

Advertising