Absolute maximum ratings, Recommended operating conditions – Renesas HD74HC1G66 User Manual

Page 3

Advertising
background image

HD74HC1G66

Rev.8.00, Jan.27.2004, page 3 of 8

Absolute Maximum Ratings

Item

Symbol

Ratings

Unit

Test Conditions

Supply voltage range

V

CC

–0.5 to 7.0

V

Input voltage range *

1

V

I

–0.5 to V

CC

+ 0.5

V

Output voltage range *

1, 2

V

O

–0.5 to V

CC

+ 0.5

V

Output : H or L

Input clamp current

I

IK

±20

mA

V

I

< 0 or V

I

> V

CC

Output clamp current

I

OK

±20

mA

V

O

< 0 or V

O

>V

CC

Continuous output current

I

O

±25

mA

V

O

= 0 to V

CC

Continuous current through
V

CC

or GND

I

CC

or I

GND

±25

mA

Maximum power dissipation
at Ta = 25°C (in still air) *

3

P

T

200

mW

Storage temperature

Tstg

–65 to 150

°C

Notes:

The absolute maximum ratings are values, which must not individually be exceeded, and
furthermore, no two of which may be realized at the same time.

1. The input and output voltage ratings may be exceeded if the input and output clamp-current

ratings are observed.

2. This value is limited to 5.5 V maximum.
3. The maximum package power dissipation was calculated using a junction temperature of 150°C.

Recommended Operating Conditions

Item

Symbol

Min

Max

Unit

Test Conditions

Supply voltage range

V

CC

2

6

V

Input voltage range

V

I/O

0

V

CC

V

Output voltage range

V

O

0

V

CC

V

0

1000

V

CC

= 2.0 V

0

500

V

CC

= 4.5 V

Input rise / fall time
(Control input 10% to 90%)

t

r

, t

f

0

400

ns

V

CC

= 6.0 V

Operating temperature

Ta

–40

85

°C

Note: Unused or floating control inputs must be held high or low.