Dc sparker replacement, Power module replacement, Maintenance – Regency P40 User Manual

Page 47

Advertising
background image

Regency

®

P40-1 Direct Vent Gas Fireplace

47

MAINTENANCE

MAINTENANCE

1) Unplug the power source.

2) Remove the manual control panel by

removing the 2 screws.

3) Remove the DC Sparker by removing the 2

screws that secure the DC Sparker to the
fi rebox and lift out.

DC Sparker

4) Remove the cover on the DC Sparker and

unplug the red (+) and black (-) wires.

Note: Ensure that the ring tabs on the wire

fi t behind the metal posts when re-
installing.

5) Unplug pilot knob wires (Wa and Wb) and

ignitor wire (Vu).

DC SPARKER

REPLACEMENT

Ring Tabs

6) Replace the DC Sparker and reverse steps

to re-install.

Wa & Wb Wires

Vu Wires

Manual Control Panel

1) Unplug the power source.

2) Remove the Power Module by lifting it up off

of the velcro and pull out.

Power Module

3) Remove the Power Module cover by

removing the 2 screws, one on each side
of the box.

4) Unplug all wires connected to the Power

Module (J1, J2 & J3 on the power module
circuit board).

5) Pull Power Module off of pins and replace.

6) Reverse steps to re-install.

POWER MODULE

REPLACEMENT

J1

J2

J3

Advertising