Chapter 3 Operation

IPmux-16 Installation and Operation Manual

3-2 Operating Instructions

Table 3-1. IPmux-16 System Indicators and Switches

No Module Name Type Function

1 System RDY

LED On:

Device

OK

OFF: Self-test in progress
Blinking: Malfunction detected

2

System

PS1/PS2

LED

On: Unit powered
Off: Unit not powered

3

System

ALM

LED

Red: Alarm
Off: No alarm

4

Ethernet

LINK

LED

Off: Link not active
On: Line OK

5

Ethernet

ACT

LED

Off: No activity
On: Frame being transferred on line

6

Ethernet

100M

LED

Off: 10 MHz
On: 100 MHz

7

Ethernet

FDX

LED

Off: Half duplex
On: Full duplex

8

E1

SYNC

LED

On: Port synchronized (no alarm)
Off: Unframed - Signal loss or AIS
detected

Framed - Signal loss, loss of frame or

AIS detected

Blinking: RDI detected (remote alarm)

9

Rear panel PS1/PS2

Switch Turns IPmux-16 power on and off

3.3 Operating Instructions

Turning IPmux-16 On – Without Control Terminal

IPmux-16 power switches are located on the back panel, as shown in Figure 3-2.

To power up IPmux-16 without a terminal:
• Switch the PS1 power supply switch, located on the rear panel, to ON.

IPmux-16 can be optionally equipped with a second power supply (PS2). If

present, switch PS2 to ON.

After power-up, check the unit LED indicators, located on the right side of the

front panel, and the module indicators for proper operation (see Figure 3-1,
Figure 3-2
, and Table 3-1).