Connection procedure (see figure 3) – Renesas Converter Board R0E5212BACFK00 User Manual

Page 3

Advertising
background image

(3/4)

5. Connection Procedure (See Figure 3)


The procedure for connecting the R0E5212BACFK00 is shown
below.

(1) Mount the NQPACK064SD-ND on the user system.

(2) Attach the YQPACK064SD to the NQPACK064SD-ND.

(3) Secure the four corners of the YQPACK064SD with the

YQ-GUIDE's.

Do not use the screws included with the

YQPACK064SD for fixing the YQPACK064SD.

The screwdriver included with the

NQPACK064SD-ND is used for fixing the

HQPACK064SD. Do not use it for fixing the

YQ-GUIDE's.

(4) Attach the R0E521000EPB00 or R0E521000CPE00 to the

R0E5212BACFK00.

(5) Attach the R0E5212BACFK00 to the YQPACK064SD.


64-pin 0.5mm pitch

(PLQP0064KB-A) foot pattern

YQ-GUIDE(×4)

YQPACK064SD

NQPACK064SD-ND

(1)

(2)

(4)

(5)

R0E5212BACFK00

(3)

V

Be sure to use a
flathead screwdriver

R0E521000EPB00

or

R0E521000CPE00

Figure 3 Connection procedure of the R0E5212BACFK00

6. External Dimensions and a Sample Foot Pattern (See Figure 4)


Figure 4 External dimensions and a sample foot pattern of the R0E5212BACFK00

35.0

16

.5

32

.0

0.25

0.5

10.0

14.0

10

.0

14.0

Unit: mm

R0E5212BACFK00 REV.A

MADE IN JAPAN