ritetemp 401-014 User Manual

Page 8

Advertising
background image

PG

14

PG

13

From Furnace
and AC unit

G

W

Y

RH

RC

C

R

G

Y

W

C

RH

or

From Furnace
and AC unit

STEP 1 - Connect the Y wire to the

Y terminal on the thermostat. This

connects to the Cooler compressor.

STEP 2 - Connect the RH or R wire

to the RH terminal on the thermostat.

This connects the Heater/Cooler

Power.

STEP 3 - Connect the W wire to the W terminal on the

thermostat. This connects to the heater control line.

STEP 4 - Connect the G wire to the G terminal on the

Thermostat. This connects to the Fan.

Your HVAC system is now connected to the thermostat.

STEP 1 - Remove the red Jumper

wire.

STEP 2 - Connect the Y wire to

the Y terminal on the thermostat.

This connects to the Cooler

compressor.

STEP 3 - Connect the RH wire to the RH

terminal on the thermostat. This connects to the

Heater Power .

STEP 4 - Connect the RC wire to the RC terminal on

the thermostat. This connects to the Cooling Power .

STEP 5 - Connect the W wire to the W terminal on the thermostat.

This connects to the heater control line.

STEP 6 - Connect the G wire to the G terminal on the Thermostat.

This connects to the Fan.

Your HVAC system is now connected to the thermostat.

Return To Page 7

Return To Page 7

5 WIRE

4 WIRE

NOTE: Wires marked with the dotted line are optional.

NOTE: Wires marked with the dotted line are optional.

HVAC SYSTEM

jumper
wire

Heat

Power

Heat

W

G

RH

C

FAN

Y

Cool

Comp

Thermostat

HVAC SYSTEM

Remove
jumper
wire

HEAT
Power

Heat

W

G

RH

RC

C

FAN

Y

Cool

Comp

COOL
Power

Thermostat

A

A

Advertising