Rinnai REU-VB2735WD-US User Manual

Page 2

Advertising
background image

R94LSe (VB2735WD-US)

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us

Water Temperature Control

Controller




Controller Cable

Safety Devices


Clearances from Combustibles

Clearances from Non-combustibles

* 24 inches required for serviceability

Min. / Max. Gas Supply Pressure


Manifold Gas Pressure (inches W.C.)
(sea level)

NOx

Warranty

Simulation feed forward and feedback

MC-91-1US (included)
Deluxe controller: MC-100V-1US (optional)
Bathroom controller: BC-100V-1US (optional)
MCC-91-1US (for commercial applications)

Non-polarized two-core cable, minimum 22 AWG

• Flame failure - Flame Rod

• Boiling protection

• Combustion fan rpm check
• Over current - glass fuse (3 amp)
• Top of heater - 12 inches

• Front (Panel) - 24 inches
• Front (Exhaust) - 24 inches
• Top of heater - 2 inches
• Front (Panel) - 0 inches *
• Front (Exhaust) - 24 inches

Natural Gas: min 5” W.C.

max 10.5” W.C.

Propane Gas: min 8” W.C.

max 13.5” W.C.

Natural Gas: high fire 2.8” W.C. low fire 0.44” W.C.
Propane Gas: high fire 5.0” W.C. low fire 0.93” W.C.

Meets California and Texas NOx Emission Rules

Heat exchanger: 12 years* for residential and 5 years* for
commercial and hydronic applications; (10 years* if used with the
Rinnai Hydronic Air Handler); all other parts 5 years*; labor 1 year;
(* 3 years if used as a circulating water heater within a circulation
loop, when the water heater is in series with a circulation system
and all circulating water flows through the water heater)

DIMENSIONS

Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior
notice. Local, state, provincial and federal codes must be adhered to prior to installation.

WEIGHT: 51 LBS (23 KG)

• Remaining flame (OHS)

• Thermal fuse
• Automatic frost protection

• Back of heater - 0 inches
• Ground / bottom - 12 inches
• Sides of heater - 6 inches
• Back of heater - 0 inches

• Ground / bottom - 2 inches
• Sides of heater - 1/8 inch

A

C

D

E

F

H

G

J

I

B

K

DIM DESCRIPTION R75LSe

R94LSe

A Width

14

(355.6)

B Depth

9.9

(251.1)

C Height - Unit

22.9 (582)

D Height - with brackets

25.0 (634.2)

E Hot Water Outlet - from wall

3.8 (97.6)

F Hot Water Outlet - from center

4.3 (110)

G Cold Water Inlet - from wall

3.0 (76.6)

H Cold Water Inlet - from center

1.1 (27)

I

Gas Connection - from wall

4.2 (105.6)

J Gas Connection - from center

3.5 (89)

From base to gas connection

1.6 (40)

K From base to cold connection

2.0 (50)

From base to hot connection

1.6 (41)

Advertising