Regency Liberty L900 Gas Fireplace L900-LP1 User Manual

Regency liberty l900 gas fireplace, Warning

Advertising
background image

Model

L900-NG1

L900-LP1

Fuel Type

Natural Gas

Propane

Minimum Supply Pressure

5” W.C.(1.25 kPa)

12” W.C. (3.00 kPa)

Manifold Pressure - High

3.5” W.C. (0.87 kPa)

10” W.C. (2.49 kPa)

Manifold Pressure - Low

1.6” W.C. (0.40 kPa)

6.4” W.C. (1.59 kPa)

Orifi ce Size

#30 DMS

#49 DMS

Minimum Input
Altitude 0-4500 ft. (0-1372m)

28,000 BTU/h (8.20 kW)

31,000 BTU/h (9.08 kW)

Maximum Input
Altitude 0-4500 ft. (0-1372m)

41,500 BTU/h (12.16 kW)

38,500 BTU/h (11.28 kW)

Vent Sizing

5” Inner / 8” Outer

5” Inner / 8” Outer

Unit Dimensions

Description

L900-1

A

Firebox Width w/ Standoff

51-1/2” (1308mm)

B

Rear Firebox Width

40-5/8” (1032mm)

C

Firebox Height

41-3/8” (1051mm)

D

Height w/ Standoff

50-3/8” (1270mm)

E

Unit Depth

27” (686mm)

F

Height to Vent

44-1/2” (1130mm)

G

Fireplace Opening Height

32-1/16” (814mm)

H

Fireplace Opening Width

33-5/8” (853mm)

I

Height to Fireplace Opening

3” (76mm)

L900-1 Gas Fireplace

Approved Venting Systems

Flex Vent Systems:

FPI AstroCap™ Flex Vent

Rigid Pipe Vent Systems:

Simpson Direct Vent Pro®
Selkirk Direct-Temp™
Metal-Fab® Sure Seal

Regency Liberty L900 Gas Fireplace

Unit Dimensions:

Framing Dimensions:

Non-Combustible Requirements:

Framing Dimensions

Description

L900-1

J

Framing Width

52” (1321mm)

K

***

Framing Height

***

50-3/4” (1289mm)

***

+ Hearth

L

Framing Depth

26-1/2” (673mm)

M

Minimum Height to Combustibles

60” (1524mm)

N

Corner Wall Length

63-15/16” (1624mm)

O

Corner Facing Wall Width

90-7/16” (2286mm)

P

Vent Centerline Height

53” (1346mm)

Q

Non-combustible facing height

17-7/16” (443mm)

R

Gas Connection Opening Height

2” (51mm)

S

Gas Connection Height

11-1/4” (286mm)

T

Gas Connection Inset

6” (152mm)

U

Gas Connection Opening Width

5” (127mm)

***

Important: Framing height requires consideration of the hearth

depth. Dimension K = K + the thickness of installed hearth.

WARNING

Failure to maintain required clearances is a major cause of chimney related fi res.
Installation of this fi replace must comply with these clearances
Please note:
Due to ongoing product development, product appearance and specifi cations
are subject to change without notice.

This manual is intended to be a Sales Reference Guide only.
Do NOT use for actual framing and installation of any unit.
Some specifi cations may change without notice.
You must use the actual manual for exact installation specifi cations.