7 downloading firmware, 1 when it is necessary to download firmware, 2 downloading firmware in maintenance mode – Renesas Emulation Probe for M32C/87 Group M30870T-EPB User Manual

Page 26: Important

Advertising
background image

M30870T-EPB User’s Manual

2. Setup

REJ10J0482-0300 Rev.3.00 February 16, 2006

2.7 Downloading Firmware


2.7.1 When It is Necessary to Download Firmware
It is necessary to download the firmware in the cases listed below. Normally, the following are automatically detected when
the emulator debugger is started up, and the firmware is downloaded.
(1) When you use this product for the first time
(2) When the firmware has been upgraded
(3) When the emulator debugger has been upgraded
(4) When you use this product with a PC7501 which was used with other emulation probe before
If downloading firmware is not completed in the cases below, redownload the firmware.
- When the power is unexpectedly shut down during a download from the emulator debugger
- When a communications interface cable is unexpectedly pulled out

2.7.2 Downloading Firmware in Maintenance Mode
Download the firmware in maintenance mode as explained here following. The user system must not be connected when

downloading the firmware.
(1) Set the interface select switch on the rear panel of the PC7501 to the LPT side and connect the LPT parallel interface cable

to the PC7501 and the host machine.

(2) Within 2 seconds of activating power to the emulator, press the RESET switch on the PC7501 upper panel to switch to

maintenance mode.

Switched to maintenance mode, the SAFE SYSTEM STATUS LED begins to flash.

(3) Start up the emulator debugger. When the Init dialog box setup is complete, the dialog which urges to download the

firmware will appear. Download the firmware following messages. Required time for downloading the firmware is about
60 seconds.


Figure 2.5 Downloading firmware in maintenance mode

IMPORTANT

Note on Downloading Firmware:

Do not shut OFF power while the firmware is being downloaded. Doing so, the emulator will not start up

properly. If power is shut OFF by mistake, redownload the firmware in maintenance mode.

Downloading firmware started

Maintenance mode started

Download terminated

: ON

: OFF

: Flashing

POWER

POWER

SAFE

ERROR

CLOCK
RESET

RUN

WARNING

TARGET

STATUS

SYSTEM

STATUS

SYSTEM

POWER

POWER

SAFE

ERROR

CLOCK
RESET

RUN

WARNING

TARGET

STATUS

STATUS

POWER

POWER

SAFE

ERROR

CLOCK
RESET

RUN

WARNING

TARGET

STATUS

SYSTEM

STATUS

POWER

POWER

SAFE

ERROR

CLOCK
RESET

RUN

WARNING

TARGET

STATUS

SYSTEM

STATUS

SYSTEM

POWER

POWER

SAFE

ERROR

CLOCK
RESET

RUN

WARNING

TARGET

STATUS

STATUS

Page 26 of 104

Advertising