Auto function, Option (installer adjust mode), Pre l iminar y – Runco SP-50 User Manual

Page 53

Advertising
background image

Operation

Runco CinemaWall SP-42/-50/-60 Owner’s Operating Manual

43

PRE

L

IMINAR

Y

Auto Function: The CinemaWall can automatically switch to Input 1 or Input 4 (Model
SP-50/SP-60 only) when an image signal is detected at that input. To enable this feature,
select Auto Function from the Option menu and set it to INPUT 1 (or INPUT 4, on a
Model SP-50/SP-60).

After Auto Function triggers an input switch, when the Input 1 or Input 4 signal is no longer
present, the input source reverts to the previously-selected input.

Option (Installer Adjust
Mode)

Program Timer (SP-42) / Screen Maint. (SP-50/SP-60): When in Installer Adjust
mode, select Program Timer (SP-42) / Screen Maint. (SP-50/SP-60) from the Option
menu to program the screen maintenance features of the CinemaWall to operate at
regular intervals. This is useful for preventing image burn-in.

You can program the CinemaWall to switch inputs and/or replace the normal source
signal with a white field, an inverse image or an “orbiting” image. You can specify a time of
day and day of the week when you want this to take place.

To set up a screen maintenance program:

1. Press SET to select the DATE field for the first program. Press

or

to select one of

the following:

• SUN, MON, TUE, WED, THU, FRI or SAT for a program that runs once only on the

next occurrence of that day.

• * for a program that runs daily.

• *SUN, *MON, *TUE, *WED, *THU, *FRI or *SAT for a program that runs weekly on

that day.

2. Press SET, then

followed by SET again to set the program start time.

3. Press

or

to set the hour component of the start time.

4. Press

, then

or

to set the minute component of the start time.

5. Press SET, then

followed by SET again to set the program end time (repeat steps 3

and 4).

6. Press SET, then

followed by SET again to specify an input associated with this

program. Choose “–” to specify the input that was active when the CinemaWall was
last powered off.

7. Press SET, then

followed by SET again to select the PATTERN field for this

program. Press

or

to select one of the following:

• Choose “–” to specify the function that was active when the CinemaWall was last

powered off.

• Choose WHITE to display a white field.

• Choose INVERSE to display an inverse image.

• Choose ORBITER to display an “orbiting” image.

On the Model SP-42, Auto Function is supported on Input 1 only.
The input signal must be RGB with composite or separate sync;
Auto Function will not work with sync-on-green RGB or component
signals.

When Auto Function is active, selecting an input manually causes
Auto Function to be temporarily disabled. If you cycle power to the
CinemaWall, Auto Function becomes active again.

Note

INPUT 3

INSTALLER ADJ.

SCREEN

SET-UP

OPTION

PICTURE

PROGRAM TIMER

TEST PATTERN

: OFF

SIDEBAR ADJ.



BAUD RATE

: 9600BPS

ID NUMBER

: ALL

ENTER

SET

EXIT

MENU

PROGRAM TIMER

DATE ON

OFF

INPUT PATTERN

*

10:00

– –:– –

*

20:00

– –:– –

WHITE

* –

–:–

21:00 – –

– –:– –

– –:– –

– –:– –

– –:– –

– –:– –

– –:– –

– –:– –

– –:– –

RETURN

ENTER

SET

EXIT

MENU