Maintenance, Log replacement, Door gasket – Regency Ultimate U39-LP1 User Manual

Page 37: Latch adjustment, Glass replacement

Advertising
background image

Regency

®

U39 ULTIMATE Direct Vent Freestanding Gas Stove

37

Mitred Glass Replacement

Removing Glass

1) Remove the door from the unit and place

on a soft surface to prevent scratching.

2) Pull out the door gasket.

3) Remove the 24 nuts holding the glass

retainers in place. Do not remove the nuts
underneath the retainers.

4) Remove the door catch plate.

5) Remove glass retainers on sides fi rst (3 each

side) then remove two center retainers.

Note: Center glass retainers are glued to

center glass.

6) Remove glass from extrusions. When

removing center glass, leave white
insulation in place.

Installing Glass

2) Place glass assembly into door frame.

3) Install retainers by placing 1 drop of glue

where previously glued and put in place.

4) Install side retainers.

5) Install door catch plate.

6) Install the 24 nuts loosely, do not tighten

yet.

1) Install both center

and side glass
onto extrusions
as per diagram.

Panel Glass Door Assembly

Wraparound Assembly Door
(same glass retainers as the

Panel Assembly)

Note: Wearing gloves will protect your hands

while handling glass.

Panel Glass Replacement

1) Remove the door from the unit and place on

a soft surface to prevent scratching.

2) Pull out the door gasket.

3) Remove the nuts holding the glass retainers

in place.

4) Remove the glass retainers (sides, top and

bottom) and the door catch plate.

5) Replace the glass. The glass must have

gasketing around it.

6) Reverse the previous steps, replace the

retainers and fasten with the nuts but do
not overtighten, as this can break the glass.
Note: the door catch plate fi ts on top of the
left side retainer.

7) Put gasket glue on the retainers, but do not

put glue on the screws. Replace the door
gasket, the two ends butt tight together on
the bottom edge of the door.

8) Replace door on the stove and check the

seal.

LOG REPLACEMENT

The unit should never be used with broken logs.
Turn off the gas valve and allow the unit to cool
before opening door to carefully remove the
logs. The pilot light generates enough heat to
burn someone. If for any reason a log should
need replacement, you must use the proper
replacement log. The position of these logs
must be as shown in the diagram under Log
Installation.

Note: Improper positioning of logs may

create carbon build-up and will alter
the unit’s performance which is not
covered under warranty.

DOOR GASKET


If the door gasket requires replacement use 7/8"
diameter oval door gasket (Part # 650-920).

LATCH ADJUSTMENT

The door latch may require adjustment as the
door gasket material compresses after a few fi res
and after glass replacement. Turn the adjustable
catch to tighten or loosen the latch.

GLASS

REPLACEMENT

Your ULTIMATE stove is supplied with high
temperature, 5 mm Neoceram ceramic glass that
will withstand the highest heat that your unit will
produce. In the event that you break your glass
by impact, purchase your replacement door from
an authorized Regency

®

dealer only, and follow

our step-by-step instructions for replacement.
The glass is not sold separately, as it must be
properly sealed in the door frame.

Replacement Part #

940-325/P U39

Wraparound

Glass

940-322/P

U39 Panel Center Glass

940-323/P

U39 Panel Side Glass

WARNING: Do not operate appliance
with glass panels removed, cracked
or broken. Replacement of the glass
should be done by a licensed or
qualifi ed service person.

MAINTENANCE

Advertising
This manual is related to the following products: