Electrical Characteristics

T

a

= 25°C

T

a

= –40 to 85°C

Item Symbol

V

CC

(V)

Min Typ Max Min Typ Max

Unit Test

Conditions

3.0

to

3.6

— — — 1.5 — —

V

IH

4.5 to 5.5

— — — 2.0

— —

3.0

to

3.6

— — — — — 0.6

Input voltage

V

IL

4.5 to 5.5

— — — — — 0.8

V

Control input only

3.3 — — — —

0.10

Hysteresis
voltage

V

H

5.0 — — — —

0.15

V V

T

+

– V

T

3.0 —

50

150

190

On-state switch
resistance

R

ON

4.5 —

40

75

100

V

IN

= V

CC

or GND

V

C

= V

IH

I

T

= 1 mA

3.0

— 100 180 — — 225

Peak on
resistance

R

ON (P)

4.5 —

50

100

125

V

IN

= V

CC

to GND

V

C

= V

IH

I

T

= 1 mA

Off-state switch
leakage current

I

s (OFF)

5.5 — —

±0.1

— —

±1.0

µ

A

V

IN

= V

CC

, V

OUT

= GND

or V

IN

= GND,

V

O

= V

CC

, V

C

= V

IL

On-state switch
leakage current

I

s (ON)

5.5 — —

±0.1

— —

±1.0

µ

A

V

IN

= V

CC

or GND

V

C

= V

IH

Input current

I

IN

0 to 5.5

±0.1

±1.0

µ

A V

IN

= 5.5 V or GND

I

CC

5.5 — — — — — 10

µ

A V

IN

= V

CC

or GND

Quiescent
supply current

I

CC

5.5 — — — — — 1.5 mA

V

IN

= 3.4 V

Control input
capacitance

C

IC

— 3.5 — — — — pF

Switch terminal
capacitance

C

IN / OUT

— 4.0 — — — — pF

Feed through
capacitance

C

IN–OUT

— 0.5 — — — — pF

Switching Characteristics

V

CC

= 3.3 ± 0.3 V

Ta = 25°C

Ta = –40 to 85°C

Item Symbol

Min Typ Max Min Max

Unit

Test

Conditions

FROM

(Input)

TO

(Output)

— 1.5

6.0 — 10.0

C

L

= 15 pF

Propagation
delay time

t

PLH

t

PHL

— 4.0

9.0 — 12.0

ns

C

L

= 50 pF

IN/OUT

or OUT/IN

OUT/IN

or IN/OUT

— 4.0

11.0 — 15.0

C

L

= 15 pF

Enable time

t

ZH

t

ZL

— 6.0

18.0 — 22.0

ns

C

L

= 50 pF

C

IN/OUT

or OUT/IN

— 5.0

11.0 — 15.0

C

L

= 15 pF

Disable time

t

HZ

t

LZ

— 8.0

18.0 — 22.0

ns

C

L

= 50 pF

C

IN/OUT

or OUT/IN

V

CC

= 5.0 ± 0.5 V

Ta = 25°C

Ta = –40 to 85°C

Item Symbol

Min Typ Max Min Max

Unit

Test

Conditions

FROM

(Input)

TO

(Output)

— 1.0 4.0 — 7.0

C

L

= 15 pF

Propagation
delay time

t

PLH

t

PHL

— 3.0 6.0 — 8.0

ns

C

L

= 50 pF

IN/OUT

or OUT/IN

OUT/IN

or IN/OUT

— 3.0 7.0 — 10.0

C

L

= 15 pF

Enable time

t

ZH

t

ZL

— 5.0

12.0 — 16.0

ns

C

L

= 50 pF

C

IN/OUT

or OUT/IN

— 4.0 7.0 — 10.0

C

L

= 15 pF

Disable time

t

HZ

t

LZ

— 6.0

12.0 — 16.0

ns

C

L

= 50 pF

C

IN/OUT

or OUT/IN

Advertising